Recognising window condensation: where the moisture forms and what it means
Fogging on the inside faces: what to note (morning, corners, runoff)
With window condensation on the inside, note the time of day (often at daybreak), the location (bottom of the glazing, corners, reveals) and the severity (haze, droplets, runoff). Record indoor relative humidity, room temperature, surface temperature at the edge of the glazing and look for cold spots (thermal bridge, roller shutter box). To substantiate the diagnosis, you can rely on a dew point calculation. After replacing windows and doors, also check the extract airflow rate and the balance of the air inlets.
Outside-side condensation: when the window is performing… and why it surprises the client
Outside-side fogging appears mainly in the early morning. High-performance glazing limits heat losses from the inside. The outer face can then fall below the outdoor dew point due to radiative cooling. This is a sign of performance, not a sealing defect. Explain this before starting unnecessary remedial work.
Condensation between the panes: the case of “dead” double glazing (loss of airtightness)
Persistent fogging or streaking between the two panes indicates a loss of airtightness at the spacer. The desiccant is saturated and the unit becomes a dead insulating glass unit. Note this in the report and deal with it by replacing the insulating glass unit, not by adjusting ventilation.
Interior condensation on the glazing: excess humidity + ventilation, or a cold surface?
Indoor humidity too high: everyday activities, drying laundry, wet rooms
Diffuse window condensation, especially in the early morning, often points to excessive moisture load. On site, measure relative humidity room by room and identify the sources. Kitchen, showers, drying laundry, adjoining cellars. Record it in your report to justify the next steps.
Insufficient ventilation: MVHR, air inlets, terminals, door undercuts
If moisture cannot escape, it ends up on the glass. Check the MVHR is operating and that air transfer paths are continuous.
- Terminals and ducts are not clogged and not blocked.
- Air inlets are present and unobstructed, and suitable for the joinery.
- Door undercuts and transfer paths are present, especially to wet rooms.
Cold surface and thermal bridge around the window: reveal, lintel, roller shutter box
Localised condensation at the perimeter, in a lower corner or by the shutter box. Look for a cold surface or a thermal bridge. Check the reveal, lintel and the roller shutter box (insulation continuity, air-tightness, defective remediation). A surface temperature reading or an IR camera will quickly show you the area to treat.
Exterior condensation on the glazing: the argument to give your client in 2026
Why condensation on double glazing can appear outside: better insulation, colder surface in the morning
On a high-performance window, the outer face of the glazing can drop below the dew point at dawn. Double glazing reduces heat leakage from the heated space. The external surface therefore receives less heat and cools more quickly, especially under a clear sky. The result is that window condensation on the street side can be a sign of good insulation, not a defect.
What distinguishes outdoor dew from a window defect: duration, weather, exposure, shading (trees, blinds)
- Duration: temporary phenomenon, typically 30 to 120 minutes after sunrise.
- Weather: clear, humid nights, little wind. Cloud cover reduces dew.
- Exposure: more noticeable on north- and east-facing windows. Sunlight makes it disappear quickly.
- Shading: trees, blinds, roof overhangs, partially lowered roller shutters. Anything that “cuts off” the sky reduces radiative cooling. To go further on the effect of shading by orientation, see solar shading blinds according to orientation.
How to answer the objection “new window = problem”: the on-site proof checklist
On site, check
- Morning weather reading and time-stamped photos, before and after sunlight.
- Location. Outside only, with no water marks at the bottom of the frame.
- Comparison. More exposed glazing versus glazing under shade.
- Measurement. Surface temperature with an infrared thermometer and dew point (T/RH probe).
- Exclusion. If the fogging is between the panes, it is a failed insulating glass unit, not external dew.
Fogging between the panes: diagnosing irreparable double glazing condensation
Typical symptoms: persistent fogging, streaks, halos, impossible to wipe off
The fogging is trapped in the air or gas cavity. It remains visible whatever you do to the accessible faces. Simple site test. Wipe the inside and outside with no effect, diffuse streaks or recurring halos, milky appearance in cold or sunny weather. This is window condensation “between panes”, and it must be distinguished from interior condensation caused by the dew point on a cold surface.
Common causes: seal failure, ageing, impact, manufacturing defect, installation
In the vast majority of cases, it is a loss of airtightness in the insulating glass unit. Ageing of perimeter sealants, thermal cycles, UV exposure, water ingress around the perimeter, impact on the sash, distortion of the rebate. Less often, a manufacturing defect (spacer, desiccant) or installation stress. The result: gas leakage, saturated desiccant, trapped moisture.
What solution to propose: replace the glazing unit (and when to replace the whole window)
Site solution. Replace the insulating glass unit, recording thickness, setting, low-e coating orientation, and the overall dimensions. Move to full window replacement if the beads are non-removable, the rebate is degraded, the sash is twisted, the hardware is at end of life, or if several units fail on an old frame. A “dead” glazing unit cannot be repaired: in that case, compare options via full replacement versus glazing replacement.
“Humidity and ventilation” cluster: linking the symptoms and pointing to the right action
Quick decision tree: inside versus outside versus between panes (5-minute diagnosis)
Start by locating the window condensation. If it is on the inside face and disappears after restarting the MVHR or airing out the room, you are dealing with excess vapour or a surface that is too cold. If it is on the outside face, early in the morning, and disappears in the sun, it is often a sign of high-performance glazing. If the fogging is persistent between the panes, the insulating glass unit is at end of life: glazing action required.
Immediate actions without works: ventilation, MVHR adjustment, managing moisture sources
During the visit, check the air inlets, door undercuts and the condition of the terminals. Verify duct continuity, the boost mode in wet rooms and any timer settings. Take stock of the sources. Laundry drying, cooking, showering. Then decide. Adjustment, balancing, or a written user instruction in the handover report.
When to go further: humidity measurement, thermal bridge search, global survey
If there is still doubt, measure humidity and surface temperature around the window frame. Look for a thermal bridge in the reveal, lintel, shutter box, or an abnormal pressure drop. If several rooms are affected, move to a ventilation assessment and a ventilation diagnosis and a full survey to define a works plan.