Features / Solar PV

Solar PV

Sell solar PV with figures, not promises

Request a demo

No commitment, 30-minute demo

Time:

Panels laid out on the roof, output estimated from orientation and tilt, self-consumption and export simulated: Argile turns your PV study into a sales argument.

01

Laid out on the roof

layout drawn plane by plane on the satellite view, with the obstacles surveyed on the roof and shading replayed month by month, hour by hour

South pitch

SOUTH · 30°

4,280 kWh

North pitch

NORTH · 30°

0 kWh

Panels

8

Output

4.0 kWp

02

Output estimated per array

every module group carries its own peak capacity and yearly output, from the orientation and tilt of its roof plane

Self-use

74 %

Annual saving

€652

PV output

Self-consumption

Consumption

03

Self-consumption simulation

self-consumption rate, self-sufficiency rate, savings on the bill and income from export, against the household's real consumption

Solar PV module, 500 Wp — monocrystalline

500 Wp • €162.80 · x8

Micro-inverter, 4 modules

€352.00 · x2

Inverter undersized

Panels: 2.00 kWp • Inverter max DC: 1.80 kW

04

Up-to-date panel and inverter catalogues

modules, kits, inverters, micro-inverters and batteries maintained by Argile, with the undersizing warning raised live

Air-to-air heat pump and solar PV

8 051,76 €

Solar PV installation

€5,746.40

Self-use

74 %

Autonomy

32 %

05

Combines with every other job

PV is configured in the same works plan as the heat pump, with cost and savings consolidated on the quote

They already trust us

DorémiSaint-GobainIllico TravauxCarrierCrédit Mutuel ArkéaChadapauxLa Maison des TravauxEffyCrédit AgricoleGC GruppeHomeServeDualSunEnsol

+2000

installers

price their projects with Argile

10,000

products

kept up to date in our manufacturer catalogues

The solar PV journey

Camille Martin

/

Renovation plan

/

Air-to-air heat pump and solar PV

/

Solar PV installation

Back

Solar PV installation

Save the work

1

Electricity use

2

Roof pitches

3

Panel layout

4

Equipment selection

5

Projections

Next step

What happens to the electricity produced

Self-consumption

The electricity produced is used on site. Any surplus is not resold.

Self-use + surplus resale

The electricity produced is used on site first. The unused surplus is fed to the grid and resold.

Surplus resale price

0.011

€/kWh

Full resale

The whole output is fed to the grid and resold.

Electricity contract & profile

Argile estimate

Manual entry

Electricity use estimated by Argile

9,800 kWh

Number of occupants

4

Profile

Working

Working from home

Retired

01

Electricity use

How the generated electricity is valued: self-consumption, self-consumption with export of the surplus, or full export, with the buy-back price in €/kWh. The electricity contract and the household consumption profile are pulled from the grid operator, or taken from Argile's own estimate, refined by the number of occupants, the household profile and its appliances, or from a manual entry. The tariff is set as a flat rate or as peak and off-peak hours.

Camille Martin

/

Renovation plan

/

Air-to-air heat pump and solar PV

/

Solar PV installation

Back

Solar PV installation

Save the work

Electricity use

2

Roof pitches

3

Panel layout

4

Equipment selection

5

Projections

Next step

Roof pitch details

1

South pitch

SOUTH

Pitch

30°

Covering

Mechanical tile

Sub-type

Mechanical

2

North pitch

NORTH

Pitch

30°

Covering

Mechanical tile

Sub-type

Mechanical

02

Roof pitches

Every plane drawn on the satellite view, vertex by vertex, then flat or sloped, tilt in degrees, orientation on the compass, roof covering and its sub-type. "Apply to the other planes" copies the characteristics across the whole roof.

Camille Martin

/

Renovation plan

/

Air-to-air heat pump and solar PV

/

Solar PV installation

Back

Solar PV installation

Save the work

Electricity use

Roof pitches

3

Panel layout

4

Equipment selection

5

Projections

Next step

Panel layout

Panels

8

Output

4.0 kWp

Annual prod.

4,280 kWh

Self-use

74 %

Autonomy

32 %

Annual saving

€652

1

South pitch

(8)

Solar PV module, 500 Wp — monocrystalline

x8

500 Wp • €162.80

Inverters

Micro-inverter, 4 modules

x2

€352.00

Batteries

Add a battery

03

Layout

One module group per roof plane, laid landscape or portrait, on the roof or on a mounting frame, with the spacing between panels. Inverters, micro-inverters and batteries are added in the same place, and the "With shading" view replays the solar mask month by month and hour by hour.

Camille Martin

/

Renovation plan

/

Air-to-air heat pump and solar PV

/

Solar PV installation

Back

Solar PV installation

Save the work

Electricity use

Roof pitches

Panel layout

4

Equipment selection

5

Projections

Next step

Equipment

Solar PV module, 500 Wp — monocrystalline

x8

500 Wp • €162.80

Micro-inverter, 4 modules

x2

€352.00

Inverter undersized

The peak output of the panels is above what the inverter can take.

Panels: 2.00 kWp • Inverter max DC: 1.80 kW

Batteries

Add a battery

Labour

Solar PV installation and grid connection package

€3,740.00

Accessories

Add an accessory

04

Choosing the equipment

Modules, inverters and batteries carried over from the layout, completed by the labour and accessories of your catalogues. Argile compares the peak capacity assigned to each inverter with its maximum DC rating and warns as soon as it is exceeded.

Camille Martin

/

Renovation plan

/

Air-to-air heat pump and solar PV

/

Solar PV installation

Back

Solar PV installation

Save the work

Electricity use

Roof pitches

Panel layout

Equipment selection

5

Projections

Next step

Total cost

Equipment cost

€2,006.40

Labour cost

€3,740.00

Accessories cost

€0.00

Total incl. VAT

€5,746.40

How the system performs over a year

Panels

8

Output

4.0 kWp

Annual prod.

4,280 kWh

Self-use

74 %

Autonomy

32 %

Annual saving

€652

Output and self-consumption

Day

Month

Year

27 kWh

Average daily use

12 kWh

Average daily output

PV output

Self-consumption

Consumption

05

Projections

Equipment, labour and accessory costs up to the total including VAT, then a year of operation: yearly output, self-consumption rate, self-sufficiency rate, savings on the bill, income from export and total savings. The preview lays the panels on the satellite view of the roof.

Camille Martin

/

Technical visit

/

Solar PV

Solar PV

Validate

Existing

Current roof

Current equipment

Project

Layout

PV installation

Roof window

Chimney flue

Pitches of the current roof

Document the pitches that could carry solar panels

No Linky meter

Careful, a Linky smart meter is required before a solar panel project can go ahead.

South pitch

178°

DETECTED

SOUTH

Sloped pitch

Mechanical tile

Mechanical

At the ridge

6.20 m

At the gutter

3.40 m

Roof structure

Timber, good order

Sealed tiles

No

Broken tiles

None

Loft

Reached through a hatch

North pitch

358°

NORTH

Sloped pitch

Mechanical tile

Mechanical

At the ridge

6.20 m

At the gutter

3.40 m

Roof structure

Timber, good order

Sealed tiles

No

Broken tiles

None

Loft

Reached through a hatch

Add a roof pitch

06

On the technical visit

On site, the surveyor goes over each plane again on a tablet: orientation, tilt, type and condition of the roof structure, covering and sub-type, sealed or broken tiles, height at the ridge and at the gutter, access to the loft. Obstacles, roof window and chimney flue, are dropped by hand onto the satellite view.

Cengiz Donmez, Whole-home renovation
Cengiz DonmezWhole-home renovationGroupe TILKEO50 employees

“When several teams are involved, everyone needs to work with the same information. Argile helps us standardize our visits and better manage our projects.”

These features should interest you too

The Argile building blocks that pair best with this one, from the survey through to the job site.

3D reconstruction

During the visit, Argile rebuilds the building in 3D: calibration, measurements and volumes become usable for the measurements, the 2D plan and the sizing, with no specialist equipment.

Camille Martin

/

Works plan

/

Financing

Whole-house retrofit

Generate the quote

Works

Financing

Cost of works and grants

Total cost of works

4 jobs

INSULATION

External wall insulation

18 400,00 €

Windows

3 260,00 €

HEATING AND HOT WATER

Air-to-water heat pump

14 900,00 €

Heat-recovery ventilation

1 840,00 €

Total amount

38 400 €

Grants

3 grants

MaPrimeRénov’

9 200,00 €

Energy saving certificates

3 480,00 €

Regional grant

1 520,00 €

Add a grant

Total grants

− 14 200 €

Remaining cost

Cost of works

38 400 €

Grants deducted

− 14 200 €

Grants land once the works are done: the financing plan covers the advance.

Remaining cost

24 200 €

Financing plan

How the works are paid for before the grants land at the end of the site

Loans

1 loan

Prêt Ecair

24 200 € · 15 ans · 3,4 %

Instalment

212 €

Ecair

Empruntis

Sofinco

Total borrowed

24 200 €

Advances on the grants

3 grants

The grants are advanced to the customer so they do not wait for the end of the works.

MaPrimeRénov’

9 200,00 €

Energy saving certificates

3 480,00 €

Regional grant

1 520,00 €

Total advanced

14 200 €

Personal contribution

No contribution asked on this project

Total contributed

0 €

Funding plan

Public grants, energy-saving certificate bonuses and financing built into the pricing: the customer sees the real cost of their project, what is left to pay and their monthly instalments before signing.

Heat pump sizing note

Calculated to NF EN 12831-1

General information

Beneficiary

Mrs Margaret Hughes

Email

contact@argile.ai

Phone

+44 7700 900457

Works address

7 Rosewood Close, Sheffield

Air-to-water heat pump

Model

Alféa Extensa S. 10

Make

Atlantic

Rated output

10 kW

ηs at 35 °C / 55 °C

195 % / 154 %

COP

3,5

Controller

Classe VI

EPREL no.

2491075

Heat loss of the home

6,0 kW

Output at the design temperature

5,80 kW

3,59 kW

7,78 kW

0 %

60 %

130 %

Coverage of the demand

Equipment output / heat loss of the home

97 %

Sizing of the appliance

Roofs

Transmittance W/m².K

1,8

Area

65,2

Heat loss W/K

135,0

Floors

Transmittance W/m².K

0,6

Area

63,0

Heat loss W/K

15,6

Thermal bridges

Conductivity W/K/m

0,4

Lengths m

33,4

Heat loss W/K

12,5

Façades

Transmittance W/m².K

0,9

Area

162,4

Heat loss W/K

151,4

Openings

Transmittance W/m².K

1,2

Area

5,5

Heat loss W/K

10,9

Air renewal

Air change rate h⁻¹

0,8

Heat loss W/K

102,3

Temperature difference

Outdoor design temperature

-7 °C

Heat pump cut-off temperature

5 °C

Indoor set temperature

19 °C

DeltaT

14,0 °C

Construction coefficient

Volume (area × ceiling height)

378,0 m³

Equivalent G value

1,13 W/m³/K

Sizing report

Compliant with EN 12831-1 and built from the data collected during the site visit, the sizing report comes out of the flow with no extra work, ready for the customer's file.

FAQ

Browse the answers to the most frequent questions. And if needed, our team is here to help.

Contact us

From the layout itself: Argile starts from the geometry of each plane drawn on the satellite view, its orientation and its tilt, the number of modules in each group and the catalogue reference placed on it, then from the solar mask computed over the year. Yearly output comes back for the whole installation and for each module group.

Ready to sell PV with figures?

One demo, and you see your expertise proven.

Contact us