Features / Heating and cooling, room by room

Heating and cooling, room by room

Size your air-to-air heat pumps room by room

Request a demo

No commitment, 30-minute demo

Camille Martin

/

Renovation plan

/

Air-to-air heat pump and solar PV

/

Air-to-air heat pump installation

Back

Air-to-air heat pump installation

Save the work

1

Dwelling information

2

Works

3

Equipment selection

4

Works projections

Next step

What type of heat pump

Monosplit

Multi-split

Ducted

The heat pump will be used to

Cooling

Heating

Both

Zones to heat and cool

Area to heat and cool with the heat pump *

Single

Expert

Add a room

Total floor area

0

Total volume

0

Winter setpoint temperature *

19°

20°

21°

22°

25°

ECO

STANDARD

COMFORT

COMFORT +

HIGH PERF.

Summer setpoint temperature *

20°

22°

24°

26°

28°

HIGH PERF.

COMFORT +

COMFORT

STANDARD

ECO

Indoor units placed on the floor plan, coverage rate calculated for every room, equipment picked from up-to-date catalogues: Argile industrialises your reversible air conditioning projects.

01

Size it room by room

heating and cooling demand calculated for every room, with its name, floor area and ceiling height declared in Expert mode

Floor area heated and cooled by the heat pump

Simple

Expert

Living room

250 cm

26 m²

Home office

250 cm

12 m²

Main bedroom

250 cm

15 m²

Child bedroom

250 cm

12 m²

Total floor area

65 m²

Total volume

163 m³

Indoor unit

Ground floor

Living room

02

Single-split or multi-split

outdoor and indoor units placed on the floor plan, storey by storey, each tied to its room

Output required in winter

5,2 kW

Output in summer

4,1 kW

Living room

2,5 kW

Winter coverage

104%

Summer coverage

109%

03

Winter and summer coverage

the output required for both seasons at the top of the screen, then a coverage rate per machine and per room

Daikin

4MXM68A

Default

Output

6,8 kW

COP

4,10

SEER (cooling)

8,50

SCOP (heating)

4,60

Splits

4

Price excl. VAT

2 340 €

VAT

5,5 %

Price incl. VAT

2 468,70 €

04

Up-to-date manufacturer catalogues

maintained by Argile: SCOP, SEER, COP, output, number of splits, phases and prices, with no manual entry

Facade photos

Before

After

05

Outdoor unit on the facade

before and after render on the photo of the home, to show the customer at the end of the visit

They already trust us

DorémiSaint-GobainIllico TravauxCarrierCrédit Mutuel ArkéaChadapauxLa Maison des TravauxEffyCrédit AgricoleGC GruppeHomeServeDualSunEnsol

+2000

installers

size their heat pumps with Argile

10,000

products

kept up to date in our manufacturer catalogues

The journey

Camille Martin

/

Renovation plan

/

Air-to-air heat pump and solar PV

/

Air-to-air heat pump installation

Back

Air-to-air heat pump installation

Save this job

1

Home information

2

The works

3

Choosing the equipment

4

Works projections

Next step

What kind of heat pump

Single-split

Multi-split

Ducted

The heat pump will be used to

Cool

Heat

Both

Floor area heated and cooled by the heat pump *

Simple

Expert

Living room

250 cm

26 m²

Home office

250 cm

12 m²

Main bedroom

250 cm

15 m²

Child bedroom

250 cm

12 m²

Add a room

Total floor area

65 m²

Total volume

163 m³

Winter target temperature

19°

ECO

20°

STANDARD

21°

COMFORT

22°

COMFORT +

25°

HIGH PERF.

Summer target temperature

20°

HIGH PERF.

22°

COMFORT +

24°

COMFORT

26°

STANDARD

28°

ECO

01

Home information

Type of heat pump (single-split, multi-split or ducted), intended use (cooling, heating or both), then the floor area to treat. In Expert mode, zones are declared room by room, with name, floor area and ceiling height, and the total volume recomputes on every entry.

Camille Martin

/

Renovation plan

/

Air-to-air heat pump and solar PV

/

Air-to-air heat pump installation

Back

Air-to-air heat pump installation

Save this job

Home information

2

The works

3

Choosing the equipment

4

Works projections

Next step

Type of equipment to install

Number of phases

Single

Three-phase

Unit positions

Add the indoor and outdoor units

Outdoor unit

Indoor unit

Outdoor unit

Ground floor

Indoor unit

Ground floor

Living room

Indoor unit

Ground floor

Home office

Indoor unit

First floor

Main bedroom

Indoor unit

First floor

Child bedroom

Default

Satellite view

GF

1st

Cabling

Refrigerant line

12 m

+

Electrical cable

8 m

+

02

The works

Number of phases, then the outdoor and indoor units placed on the floor plan, storey by storey. Each indoor unit is tied to its room, refrigerant and electrical runs are measured, photos and notes complete the survey.

Camille Martin

/

Renovation plan

/

Air-to-air heat pump and solar PV

/

Air-to-air heat pump installation

Back

Air-to-air heat pump installation

Save this job

Home information

The works

3

Choosing the equipment

4

Works projections

Next step

Output required in winter

5,2 kW

Output in summer

4,1 kW

Details

Volume

163 m³

Winter design temp.

−7 °C

Summer design temp.

32 °C

Equipment

Switch to a kit

1 outdoor unit

Daikin

4MXM68A

Default

Output

6,8 kW

COP

4,10

SEER (cooling)

8,50

SCOP (heating)

4,60

Splits

4

Winter coverage

103%

Summer coverage

108%

Price excl. VAT

2 340 €

VAT

5,5 %

Price incl. VAT

2 468,70 €

4 indoor units

Daikin

FTXM25R

Located in the

Living room

Output

2,5 kW

Winter coverage

104%

Summer coverage

109%

Daikin

FTXM20R

Located in the

Home office

Output

2,0 kW

Winter coverage

101%

Summer coverage

106%

Daikin

FTXM20R

Located in the

Main bedroom

Output

2,0 kW

Winter coverage

98%

Summer coverage

104%

Add a unit

Labour

1 200,00 € TTC

1 item selected

Commissioning the air-to-air heat pump

Add labour

Accessories

486,30 € TTC

3 accessories selected

Wall bracket

Refrigerant line set

Power cable

Add an accessory

03

Choosing the equipment

Output required in winter and output in summer shown at the top, with the volume and the design temperatures. Units are picked from your catalogues checked by Argile, each scored on its winter and summer coverage rate. Labour and accessories VAT included.

Camille Martin

/

Renovation plan

/

Air-to-air heat pump and solar PV

/

Air-to-air heat pump installation

Back

Air-to-air heat pump installation

Save this job

Home information

The works

Choosing the equipment

4

Works projections

Next step

Total cost

Equipment cost

5 842,00 €

Labour cost

1 200,00 €

Accessories cost

486,30 €

Total incl. VAT

7 528,30 €

Annual consumption comparison

642 €

3 210 KWH

Heat pump to install

1 840 €

9 200 KWH

Current system

1 980 €

14 500 KWH

Oil boiler

1 460 €

13 800 KWH

Gas boiler

980 €

15 200 KWH

Biomass boiler

2 310 €

11 550 KWH

Electric radiators

Coverage of heating and cooling demand

Energy supplied by the heat pump

94 %

Energy supplied by the back-up

6 %

Bivalence temperature

−0,6 °C

Short-cycling hours / year

142 h

Heating demand

Heat pump output

Cooling demand

Preview of the outdoor heat pump unit once installed

Before

After

Describe the render

Regenerate

04

Works projections

Total cost including VAT split between equipment, labour and accessories, annual consumption compared with the current system, oil, gas, biomass and electric radiators, coverage of the heating and cooling demand, and a preview of the outdoor unit on the facade.

Camille Martin

/

Technical visit

/

Heating and hot water

Air-to-air heat pump

Type of heat pump

2

Unit positions

3

Sizing

Add at least one indoor unit and one outdoor unit for the future heat pump

Indoor unit

Outdoor unit

Room

Click corner by corner around the room, then double-click to confirm

Previous

Next

05

On the technical visit

On site and on a tablet, the surveyor documents the air-to-air project in three moves: type of heat pump, position of the units, sizing. Rooms are traced with a finger, an indoor unit is dropped in each, and the pump is confirmed before the visit closes.

Cengiz Donmez, Whole-home renovation
Cengiz DonmezWhole-home renovationGroupe TILKEO50 employees

“When several teams are involved, everyone needs to work with the same information. Argile helps us standardize our visits and better manage our projects.”

These features should interest you too

The Argile building blocks that pair best with this one, from the survey through to the job site.

Air-to-water heat pump

From the site visit to a sizing report compliant with EN 12831-1: Argile guides your teams at every step, calculates the required output, picks the equipment from up-to-date catalogues and shows the customer the energy they will save.

Heat pump sizing note

Calculated to NF EN 12831-1

General information

Beneficiary

Mrs Margaret Hughes

Email

contact@argile.ai

Phone

+44 7700 900457

Works address

7 Rosewood Close, Sheffield

Air-to-water heat pump

Model

Alféa Extensa S. 10

Make

Atlantic

Rated output

10 kW

ηs at 35 °C / 55 °C

195 % / 154 %

COP

3,5

Controller

Classe VI

EPREL no.

2491075

Heat loss of the home

6,0 kW

Output at the design temperature

5,80 kW

3,59 kW

7,78 kW

0 %

60 %

130 %

Coverage of the demand

Equipment output / heat loss of the home

97 %

Sizing of the appliance

Roofs

Transmittance W/m².K

1,8

Area

65,2

Heat loss W/K

135,0

Floors

Transmittance W/m².K

0,6

Area

63,0

Heat loss W/K

15,6

Thermal bridges

Conductivity W/K/m

0,4

Lengths m

33,4

Heat loss W/K

12,5

Façades

Transmittance W/m².K

0,9

Area

162,4

Heat loss W/K

151,4

Openings

Transmittance W/m².K

1,2

Area

5,5

Heat loss W/K

10,9

Air renewal

Air change rate h⁻¹

0,8

Heat loss W/K

102,3

Temperature difference

Outdoor design temperature

-7 °C

Heat pump cut-off temperature

5 °C

Indoor set temperature

19 °C

DeltaT

14,0 °C

Construction coefficient

Volume (area × ceiling height)

378,0 m³

Equivalent G value

1,13 W/m³/K

Sizing report

Compliant with EN 12831-1 and built from the data collected during the site visit, the sizing report comes out of the flow with no extra work, ready for the customer's file.

Catalogues

/

Argile catalogue

/

Air-to-water heat pump

Argile catalogue

Add a product

Article base

Central articles, shared across all your equipment

Careful, this article is shared

This article is used in 14 products; any change will apply everywhere.

Name / Reference

Brand

Purchase cost

Selling price

VAT

Unit

Used in

Liaison frigorifique 5 m

ATL-LF05

Atlantic

68,00 €

119,00 €

5,5 %

Unit

14 products

Ballon tampon 25 L

ATL-BT25

Atlantic

142,00 €

245,00 €

5,5 %

Unit

9 products

Câble d’alimentation 3G2,5

GEN-C3G25

3,10 €

5,80 €

5,5 %

Linear metre

37 products

Support antivibratile

GEN-SAV

24,00 €

42,00 €

5,5 %

Unit

22 products

Kit hydraulique 3 voies

ATL-KH3V-08

Atlantic

186,00 €

312,00 €

5,5 %

Unit

6 products

Vase d’expansion 12 L

GEN-VE12

31,00 €

58,00 €

5,5 %

Unit

41 products

Tube PER pré-gainé Ø16

GEN-PER16

2,40 €

4,60 €

5,5 %

Linear metre

28 products

Filtre magnétique

GEN-FM22

54,00 €

96,00 €

5,5 %

Unit

33 products

Catalogues

Argile builds your price library from the catalogues of the brands you distribute: every product carries its price breakdown, equipment, labour and accessories, with technical specifications checked one by one and tariffs carried through at every range change.

FAQ

Browse the answers to the most frequent questions. And if needed, our team is here to help.

Contact us

From the demand calculated for each room and the characteristics of the unit serving it. A rate is shown separately for winter and for summer, on the outdoor unit as well as on every indoor unit.

Ready to size your air-to-air heat pumps properly?

One demo, and you see your expertise proven.

Contact us