Features / Heating and cooling, room by room
Heating and cooling, room by room
Request a demo
No commitment, 30-minute demo
Camille Martin
/
Renovation plan
/
Air-to-air heat pump and solar PV
/
Air-to-air heat pump installation
Back
Air-to-air heat pump installation
Save the work
1
Dwelling information
2
Works
3
Equipment selection
4
Works projections
Next step
What type of heat pump
Monosplit
Multi-split
Ducted
The heat pump will be used to
Cooling
Heating
Both
Zones to heat and cool
Area to heat and cool with the heat pump *
Single
Expert
Add a room
Total floor area
0 m²
Total volume
0 m³
Winter setpoint temperature *
19°
20°
21°
22°
25°
ECO
STANDARD
COMFORT
COMFORT +
HIGH PERF.
Summer setpoint temperature *
20°
22°
24°
26°
28°
HIGH PERF.
COMFORT +
COMFORT
STANDARD
ECO
Indoor units placed on the floor plan, coverage rate calculated for every room, equipment picked from up-to-date catalogues: Argile industrialises your reversible air conditioning projects.
01
Size it room by room
heating and cooling demand calculated for every room, with its name, floor area and ceiling height declared in Expert mode
Floor area heated and cooled by the heat pump
Simple
Expert
Living room
250 cm
26 m²
Home office
250 cm
12 m²
Main bedroom
250 cm
15 m²
Child bedroom
250 cm
12 m²
Total floor area
65 m²
Total volume
163 m³
Indoor unit
Ground floor
Living room
02
Single-split or multi-split
outdoor and indoor units placed on the floor plan, storey by storey, each tied to its room
Output required in winter
5,2 kW
Output in summer
4,1 kW
Living room
2,5 kW
Winter coverage
104%
Summer coverage
109%
03
Winter and summer coverage
the output required for both seasons at the top of the screen, then a coverage rate per machine and per room
Daikin
4MXM68A
Default
Output
6,8 kW
COP
4,10
SEER (cooling)
8,50
SCOP (heating)
4,60
Splits
4
Price excl. VAT
2 340 €
VAT
5,5 %
Price incl. VAT
2 468,70 €
04
Up-to-date manufacturer catalogues
maintained by Argile: SCOP, SEER, COP, output, number of splits, phases and prices, with no manual entry
Facade photos
Before
After
05
Outdoor unit on the facade
before and after render on the photo of the home, to show the customer at the end of the visit
The journey
Camille Martin
/
Renovation plan
/
Air-to-air heat pump and solar PV
/
Air-to-air heat pump installation
Back
Air-to-air heat pump installation
Save this job
1
Home information
2
The works
3
Choosing the equipment
4
Works projections
Next step
What kind of heat pump
Single-split
Multi-split
Ducted
The heat pump will be used to
Cool
Heat
Both
Floor area heated and cooled by the heat pump *
Simple
Expert
Living room
250 cm
26 m²
Home office
250 cm
12 m²
Main bedroom
250 cm
15 m²
Child bedroom
250 cm
12 m²
Add a room
Total floor area
65 m²
Total volume
163 m³
Winter target temperature
19°
ECO
20°
STANDARD
21°
COMFORT
22°
COMFORT +
25°
HIGH PERF.
Summer target temperature
20°
HIGH PERF.
22°
COMFORT +
24°
COMFORT
26°
STANDARD
28°
ECO
01
Home information
Type of heat pump (single-split, multi-split or ducted), intended use (cooling, heating or both), then the floor area to treat. In Expert mode, zones are declared room by room, with name, floor area and ceiling height, and the total volume recomputes on every entry.
Camille Martin
/
Renovation plan
/
Air-to-air heat pump and solar PV
/
Air-to-air heat pump installation
Back
Air-to-air heat pump installation
Save this job
Home information
2
The works
3
Choosing the equipment
4
Works projections
Next step
Type of equipment to install
Number of phases
Single
Three-phase
Unit positions
Add the indoor and outdoor units
Outdoor unit
Indoor unit
Outdoor unit
Ground floor
Indoor unit
Ground floor
Living room
Indoor unit
Ground floor
Home office
Indoor unit
First floor
Main bedroom
Indoor unit
First floor
Child bedroom
Default
Satellite view
GF
1st
Cabling
Refrigerant line
−
12 m
+
Electrical cable
−
8 m
+
02
The works
Number of phases, then the outdoor and indoor units placed on the floor plan, storey by storey. Each indoor unit is tied to its room, refrigerant and electrical runs are measured, photos and notes complete the survey.
Camille Martin
/
Renovation plan
/
Air-to-air heat pump and solar PV
/
Air-to-air heat pump installation
Back
Air-to-air heat pump installation
Save this job
Home information
The works
3
Choosing the equipment
4
Works projections
Next step
Output required in winter
5,2 kW
Output in summer
4,1 kW
Details
Volume
163 m³
Winter design temp.
−7 °C
Summer design temp.
32 °C
Equipment
Switch to a kit
1 outdoor unit
Daikin
4MXM68A
Default
Output
6,8 kW
COP
4,10
SEER (cooling)
8,50
SCOP (heating)
4,60
Splits
4
Winter coverage
103%
Summer coverage
108%
Price excl. VAT
2 340 €
VAT
5,5 %
Price incl. VAT
2 468,70 €
4 indoor units
Daikin
FTXM25R
Located in the
Living room
Output
2,5 kW
Winter coverage
104%
Summer coverage
109%
Daikin
FTXM20R
Located in the
Home office
Output
2,0 kW
Winter coverage
101%
Summer coverage
106%
Daikin
FTXM20R
Located in the
Main bedroom
Output
2,0 kW
Winter coverage
98%
Summer coverage
104%
Add a unit
Labour
1 200,00 € TTC
1 item selected
Commissioning the air-to-air heat pump
Add labour
Accessories
486,30 € TTC
3 accessories selected
Wall bracket
Refrigerant line set
Power cable
Add an accessory
03
Choosing the equipment
Output required in winter and output in summer shown at the top, with the volume and the design temperatures. Units are picked from your catalogues checked by Argile, each scored on its winter and summer coverage rate. Labour and accessories VAT included.
Camille Martin
/
Renovation plan
/
Air-to-air heat pump and solar PV
/
Air-to-air heat pump installation
Back
Air-to-air heat pump installation
Save this job
Home information
The works
Choosing the equipment
4
Works projections
Next step
Total cost
Equipment cost
5 842,00 €
Labour cost
1 200,00 €
Accessories cost
486,30 €
Total incl. VAT
7 528,30 €
Annual consumption comparison
642 €
3 210 KWH
Heat pump to install
1 840 €
9 200 KWH
Current system
1 980 €
14 500 KWH
Oil boiler
1 460 €
13 800 KWH
Gas boiler
980 €
15 200 KWH
Biomass boiler
2 310 €
11 550 KWH
Electric radiators
Coverage of heating and cooling demand
Energy supplied by the heat pump
94 %
Energy supplied by the back-up
6 %
Bivalence temperature
−0,6 °C
Short-cycling hours / year
142 h
Heating demand
Heat pump output
Cooling demand
Preview of the outdoor heat pump unit once installed
Before
After
Describe the render
Regenerate
04
Works projections
Total cost including VAT split between equipment, labour and accessories, annual consumption compared with the current system, oil, gas, biomass and electric radiators, coverage of the heating and cooling demand, and a preview of the outdoor unit on the facade.
Camille Martin
/
Technical visit
/
Heating and hot water
Air-to-air heat pump
Type of heat pump
2
Unit positions
3
Sizing
Add at least one indoor unit and one outdoor unit for the future heat pump
Indoor unit
Outdoor unit
Room
Click corner by corner around the room, then double-click to confirm
Previous
Next
05
On the technical visit
On site and on a tablet, the surveyor documents the air-to-air project in three moves: type of heat pump, position of the units, sizing. Rooms are traced with a finger, an indoor unit is dropped in each, and the pump is confirmed before the visit closes.

“When several teams are involved, everyone needs to work with the same information. Argile helps us standardize our visits and better manage our projects.”
These features should interest you too
The Argile building blocks that pair best with this one, from the survey through to the job site.

Air-to-water heat pump
From the site visit to a sizing report compliant with EN 12831-1: Argile guides your teams at every step, calculates the required output, picks the equipment from up-to-date catalogues and shows the customer the energy they will save.
Heat pump sizing note
Calculated to NF EN 12831-1
General information
Beneficiary
Mrs Margaret Hughes
contact@argile.ai
Phone
+44 7700 900457
Works address
7 Rosewood Close, Sheffield
Air-to-water heat pump
Model
Alféa Extensa S. 10
Make
Atlantic
Rated output
10 kW
ηs at 35 °C / 55 °C
195 % / 154 %
COP
3,5
Controller
Classe VI
EPREL no.
2491075
Heat loss of the home
6,0 kW
Output at the design temperature
5,80 kW
3,59 kW
7,78 kW
0 %
60 %
130 %
Coverage of the demand
Equipment output / heat loss of the home
97 %
Sizing of the appliance
Roofs
Transmittance W/m².K
1,8
Area m²
65,2
Heat loss W/K
135,0
Floors
Transmittance W/m².K
0,6
Area m²
63,0
Heat loss W/K
15,6
Thermal bridges
Conductivity W/K/m
0,4
Lengths m
33,4
Heat loss W/K
12,5
Façades
Transmittance W/m².K
0,9
Area m²
162,4
Heat loss W/K
151,4
Openings
Transmittance W/m².K
1,2
Area m²
5,5
Heat loss W/K
10,9
Air renewal
Air change rate h⁻¹
0,8
Heat loss W/K
102,3
Temperature difference
Outdoor design temperature
-7 °C
Heat pump cut-off temperature
5 °C
Indoor set temperature
19 °C
DeltaT
14,0 °C
Construction coefficient
Volume (area × ceiling height)
378,0 m³
Equivalent G value
1,13 W/m³/K
Sizing report
Compliant with EN 12831-1 and built from the data collected during the site visit, the sizing report comes out of the flow with no extra work, ready for the customer's file.
Catalogues
/
Argile catalogue
/
Air-to-water heat pump
Argile catalogue
Add a product
Article base
Central articles, shared across all your equipment
Careful, this article is shared
This article is used in 14 products; any change will apply everywhere.
Name / Reference
Brand
Purchase cost
Selling price
VAT
Unit
Used in
Liaison frigorifique 5 m
ATL-LF05
Atlantic
68,00 €
119,00 €
5,5 %
Unit
14 products
Ballon tampon 25 L
ATL-BT25
Atlantic
142,00 €
245,00 €
5,5 %
Unit
9 products
Câble d’alimentation 3G2,5
GEN-C3G25
—
3,10 €
5,80 €
5,5 %
Linear metre
37 products
Support antivibratile
GEN-SAV
—
24,00 €
42,00 €
5,5 %
Unit
22 products
Kit hydraulique 3 voies
ATL-KH3V-08
Atlantic
186,00 €
312,00 €
5,5 %
Unit
6 products
Vase d’expansion 12 L
GEN-VE12
—
31,00 €
58,00 €
5,5 %
Unit
41 products
Tube PER pré-gainé Ø16
GEN-PER16
—
2,40 €
4,60 €
5,5 %
Linear metre
28 products
Filtre magnétique
GEN-FM22
—
54,00 €
96,00 €
5,5 %
Unit
33 products
Catalogues
Argile builds your price library from the catalogues of the brands you distribute: every product carries its price breakdown, equipment, labour and accessories, with technical specifications checked one by one and tariffs carried through at every range change.
Browse the answers to the most frequent questions. And if needed, our team is here to help.
Contact us
From the demand calculated for each room and the characteristics of the unit serving it. A rate is shown separately for winter and for summer, on the outdoor unit as well as on every indoor unit.
One demo, and you see your expertise proven.
Contact us