Features / Hybrid heat pump sizing
Hybrid heat pump sizing
Request a demo
No commitment, 30-minute demo
Camille Martin
/
Works plan
/
Installing a hybrid heat pump
Installing a hybrid heat pump
Save the job
Home details
Works
Equipment choice
4
Projected works
Next step
Total cost
Equipment cost
8 146,60 €
Labour cost
4 200,00 €
Accessories cost
640,00 €
Total incl. VAT
12 986,60 €
Annual consumption comparison
642 €
3 210 KWH
Heat pump to install
1 840 €
9 200 KWH
Current system
1 980 €
14 500 KWH
Oil boiler
1 460 €
13 800 KWH
Gas boiler
980 €
15 200 KWH
Biomass boiler
2 310 €
11 550 KWH
Electric radiators
Coverage of the heating load
91 %
Energy delivered by the heat pump
9 %
Energy delivered by the backup
+0,1 °C
Bivalence temperature
86 h
Short-cycling hours / year
Heating load
Heat pump output
Main heating
A hybrid heat pump is not sized like an air-to-water one: the machine carries most of the heating season, the boiler takes over below the bivalence temperature, and it is that split between the two energies that decides the customer’s bill.
01
Size both at once
the heat pump and the boiler against the same computed load: the machine takes 40 to 80 % of the heat loss at the design temperature
Heat loss at the design temperature (−7 °C)
6,00 kW
2,40 kW
4,00 kW
4,80 kW
The heat pump is placed between 40 and 80 % of the heat loss; the boiler covers the rest.
Vitocal 250-A 04
Viessmann
Heat pump coverage
67 %
Vitodens 100-W 25
Viessmann
Boiler share at the coldest hour
51 %
91 %
Heat pump energy
9 %
Backup energy
+0,1 °C
Bivalence
86 h
Short cycling / year
Heating load
Heat pump output
Main heating
02
The bivalence point, computed
bivalence temperature, share of energy delivered by the heat pump, share delivered by the backup and short-cycling hours, read above the curve
Vitodens 100-W 25
Viessmann
Energy
Natural gas
Rated output
24 kW
Rpn efficiency
92 %
Rpint efficiency
95 %
Standby loss Qp0
0,10 kW
Generation efficiency
90 %
Boiler share at the coldest hour
51 %
03
The boiler described like the pump
energy, rated output, Rpn and Rpint efficiencies, standby loss Qp0: the boiler carries its ratings in the catalogue
Roofs
Transmittance W/m².K
1,8
Area m²
65,2
Heat loss W/K
135,0
Façades
Transmittance W/m².K
0,9
Area m²
162,4
Heat loss W/K
151,4
Floors
Transmittance W/m².K
0,6
Area m²
63,0
Heat loss W/K
15,6
Openings
Transmittance W/m².K
1,2
Area m²
5,5
Heat loss W/K
10,9
04
Sizing report compliant with EN 12831-1
heat loss element by element, the town’s outdoor design temperature and the coverage rate: the report comes out of the journey as one document
Annual consumption comparison
642 €
3 210 KWH
Heat pump to install
1 840 €
9 200 KWH
Current system
1 980 €
14 500 KWH
Oil boiler
1 460 €
13 800 KWH
Gas boiler
980 €
15 200 KWH
Biomass boiler
2 310 €
11 550 KWH
Electric radiators
05
What the customer sees at the end of the visit
annual consumption compared between the hybrid system and the heating in place, and the outdoor unit projected onto the photo of the facade
The journey
Camille Martin
/
Works plan
/
Installing a hybrid heat pump
Installing a hybrid heat pump
Save the job
1
Home details
2
Works
3
Equipment choice
4
Projected works
Next step
Zones to heat
Emitter coverage
105 %
Radiators
Area to heat *
130 m²
/ 151 m²
Add an emitter
Emitters in place and the dwelling’s load
6,00 kW
Heat loss of the home over the heated area
6,30 kW
105 % coverage
Estimated emitter output at the chosen water temperature
The customer’s heating preferences
Indoor set temperature
19°
20°
21°
22°
23°
Economy
Standard
Comfort
Comfort +
High performance
Flow water temperature
35°
40°
45°
50°
55°
60°
65°
70°
75°
Low temp.
Medium temp.
Recommended
High temp.
01
Home details
Zones to heat and emitters in place, indoor set point and flow temperature: Argile checks the load against the output of the existing radiators and shows the emitter coverage rate before any machine is picked.
Camille Martin
/
Works plan
/
Installing a hybrid heat pump
Installing a hybrid heat pump
Save the job
Home details
2
Works
3
Equipment choice
4
Projected works
Next step
Type of equipment to install
Split
Monobloc
Number of phases
Single-phase
Three-phase
Boiler
Boiler energy and ratings
Natural gas
Oil
Propane
Butane
LPG
Rated output
−
24 kW
+
Unit positions
Add the indoor and outdoor units
Outdoor unit
Ground floor
Indoor unit
Ground floor
Cabling
Refrigerant line
−
10 m
+
Power cable
−
8 m
+
02
Works
Configuring the heat pump and the boiler: equipment type, boiler energy among natural gas, oil, propane, butane and LPG, indoor and outdoor units placed on the floor plan, then the refrigerant and electrical runs measured.
Camille Martin
/
Works plan
/
Installing a hybrid heat pump
Installing a hybrid heat pump
Save the job
Home details
Works
3
Equipment choice
4
Projected works
Next step
Choosing the hybrid heat pump
Heat pump coverage
67 %
Viessmann
Vitocal 250-A 04
Heat pump
ηs 35 °C
191 %
ηs 55 °C
148 %
COP
3,40
Output
4,00 kW
Max temp.
60 °C
Phases
Single-phase
Price excl. VAT
5 120,00 €
VAT
5,50 %
Price incl. VAT
5 401,60 €
Viessmann
Vitodens 100-W 25
Boiler
Vitodens 100-W 25
Viessmann
Energy
Natural gas
Rated output
24 kW
Rpn efficiency
92 %
Rpint efficiency
95 %
Standby loss Qp0
0,10 kW
Generation efficiency
90 %
Boiler share at the coldest hour
51 %
Heat loss at the design temperature
6,00 kW
2,40 kW
4,00 kW
4,80 kW
The heat pump is placed between 40 and 80 % of the heat loss; the boiler covers the rest.
Coverage of the heating load
91 %
Energy delivered by the heat pump
9 %
Energy delivered by the backup
+0,1 °C
Bivalence temperature
86 h
Short-cycling hours / year
03
Equipment
Equipment picked from the catalogues Argile keeps up to date, under the heading « Choix de la pompe à chaleur hybride »: seasonal efficiency at 35°/55°, COP and output for the machine, rated output and efficiencies for the boiler, services and accessories added inclusive of VAT.
Camille Martin
/
Works plan
/
Installing a hybrid heat pump
Installing a hybrid heat pump
Save the job
Home details
Works
Equipment choice
4
Projected works
Next step
Total cost
Equipment cost
8 146,60 €
Labour cost
4 200,00 €
Accessories cost
640,00 €
Total incl. VAT
12 986,60 €
Annual consumption comparison
642 €
3 210 KWH
Heat pump to install
1 840 €
9 200 KWH
Current system
1 980 €
14 500 KWH
Oil boiler
1 460 €
13 800 KWH
Gas boiler
980 €
15 200 KWH
Biomass boiler
2 310 €
11 550 KWH
Electric radiators
Coverage of the heating load
91 %
Energy delivered by the heat pump
9 %
Energy delivered by the backup
+0,1 °C
Bivalence temperature
86 h
Short-cycling hours / year
Heating load
Heat pump output
Main heating
04
Project projections
Total cost including VAT, annual consumption compared with the other energies, and hourly coverage of the load: energy delivered by the heat pump, energy delivered by the backup, bivalence temperature and short-cycling hours over the year.

“When several teams are involved, everyone needs to work with the same information. Argile helps us standardize our visits and better manage our projects.”
These features should interest you too
The Argile building blocks that pair best with this one, from the survey through to the job site.

Air-to-water heat pump
From the site visit to a sizing report compliant with EN 12831-1: Argile guides your teams at every step, calculates the required output, picks the equipment from up-to-date catalogues and shows the customer the energy they will save.
Heat pump sizing note
Calculated to NF EN 12831-1
General information
Beneficiary
Mrs Margaret Hughes
contact@argile.ai
Phone
+44 7700 900457
Works address
7 Rosewood Close, Sheffield
Air-to-water heat pump
Model
Alféa Extensa S. 10
Make
Atlantic
Rated output
10 kW
ηs at 35 °C / 55 °C
195 % / 154 %
COP
3,5
Controller
Classe VI
EPREL no.
2491075
Heat loss of the home
6,0 kW
Output at the design temperature
5,80 kW
3,59 kW
7,78 kW
0 %
60 %
130 %
Coverage of the demand
Equipment output / heat loss of the home
97 %
Sizing of the appliance
Roofs
Transmittance W/m².K
1,8
Area m²
65,2
Heat loss W/K
135,0
Floors
Transmittance W/m².K
0,6
Area m²
63,0
Heat loss W/K
15,6
Thermal bridges
Conductivity W/K/m
0,4
Lengths m
33,4
Heat loss W/K
12,5
Façades
Transmittance W/m².K
0,9
Area m²
162,4
Heat loss W/K
151,4
Openings
Transmittance W/m².K
1,2
Area m²
5,5
Heat loss W/K
10,9
Air renewal
Air change rate h⁻¹
0,8
Heat loss W/K
102,3
Temperature difference
Outdoor design temperature
-7 °C
Heat pump cut-off temperature
5 °C
Indoor set temperature
19 °C
DeltaT
14,0 °C
Construction coefficient
Volume (area × ceiling height)
378,0 m³
Equivalent G value
1,13 W/m³/K
Sizing report
Compliant with EN 12831-1 and built from the data collected during the site visit, the sizing report comes out of the flow with no extra work, ready for the customer's file.
Catalogues
/
Argile catalogue
/
Air-to-water heat pump
Argile catalogue
Add a product
Article base
Central articles, shared across all your equipment
Careful, this article is shared
This article is used in 14 products; any change will apply everywhere.
Name / Reference
Brand
Purchase cost
Selling price
VAT
Unit
Used in
Liaison frigorifique 5 m
ATL-LF05
Atlantic
68,00 €
119,00 €
5,5 %
Unit
14 products
Ballon tampon 25 L
ATL-BT25
Atlantic
142,00 €
245,00 €
5,5 %
Unit
9 products
Câble d’alimentation 3G2,5
GEN-C3G25
—
3,10 €
5,80 €
5,5 %
Linear metre
37 products
Support antivibratile
GEN-SAV
—
24,00 €
42,00 €
5,5 %
Unit
22 products
Kit hydraulique 3 voies
ATL-KH3V-08
Atlantic
186,00 €
312,00 €
5,5 %
Unit
6 products
Vase d’expansion 12 L
GEN-VE12
—
31,00 €
58,00 €
5,5 %
Unit
41 products
Tube PER pré-gainé Ø16
GEN-PER16
—
2,40 €
4,60 €
5,5 %
Linear metre
28 products
Filtre magnétique
GEN-FM22
—
54,00 €
96,00 €
5,5 %
Unit
33 products
Catalogues
Argile builds your price library from the catalogues of the brands you distribute: every product carries its price breakdown, equipment, labour and accessories, with technical specifications checked one by one and tariffs carried through at every range change.
Browse the answers to the most frequent questions. And if needed, our team is here to help.
Contact us
Below the bivalence temperature. Argile computes it from the hourly simulation and shows it above the coverage curve, along with the share of energy delivered by the heat pump and the share delivered by the backup.
One demo, and you see your expertise proven.
Contact us