Features / On-site design

On-site design

The site visit that fills in the file for you

Request a demo

No commitment, 30-minute demo

On-site design

On a phone, the technician documents the home and the project job by job: surveys, photos, equipment positions and sizing confirmed on the spot, with nothing to re-enter back at the office.

01

A guided flow for every job

impossible to forget a figure the sizing needs

Technical visit

Dwelling

Façades

Ground floors

Upper floors

Heating and hot water

Ventilation

Photovoltaics

Electricity

Add / remove a section

Client project

Sections open according to the works selected, and nothing is confirmed while a figure is missing.

Photos of the visit

3

Photo of the façade

2

Photo of the boiler

1

Photo of the electricity meter

2

Photo of the planned location

Filed with the item they document

02

Surveys and photos attached to the file

facades, rooms, existing systems, future locations

Unit positions

UE

UI

Indoor unit

Outdoor unit

Room

Core drilling

Indoor unit

Outdoor unit

03

Equipment positioned on the plan

right during the visit

Estimated heating demand

18,2 kW

Design temperature −7 °C

Daikin Altherma 3 H HT 18 kW

Output at design temp. 18,0 kW

99 %

Coverage

Calculation confirmed with the client, in the home

04

Sizing confirmed on the spot

the customer is left with a concrete project

What the visit fills in

Technical visit

Heated area

Heat losses

Emitters

Unit positions

Quote

Sizing note

Nothing to retype back at the office

05

Nothing to re-enter

the visit feeds the quote and the sizing report automatically

They already trust us

DorémiSaint-GobainIllico TravauxCarrierCrédit Mutuel ArkéaChadapauxLa Maison des TravauxEffyCrédit AgricoleGC GruppeHomeServeDualSunEnsol

+2000

installers

run their site visits with Argile

10,000

products

kept up to date in our manufacturer catalogues

The site visit, step by step

Heating and domestic hot water

18,2 kW

Leave

Current installation

Future heating

Future hot water

Boiler room

Access to the boiler room

Enough room

Yes

Boiler room dimensions

Unheated room

Floor area

14,40 m²

Volume

34,56 m³

Generator

Main

Gas

Gas condensing boiler

Domestic hot water production

Domestic hot water is produced by the main heating generator.

01

State of the home

Rooms, emitters and existing systems documented on the spot.

Heat pump project

Document the air-to-water heat pump project

1

Zone to heat

2

Rooms & emitters

3

Unit positions

4

Sizing

Heat pump

Air-to-water heat pump

Select the future emitter type

Radiators

Underfloor heating

+

Radiators & underfloor heating

Choose a setpoint temperature

19 °C

Back

Confirm

02

The customer's project

Choice of job and configuration of the future equipment.

Heat pump project

Document the air-to-water heat pump project

Zone to heat

Rooms & emitters

3

Unit positions

4

Sizing

Add at least one indoor unit and one outdoor unit of the future heat pump

UE

UI

Indoor unit

Outdoor unit

Room

Core drilling

Indoor unit

Outdoor unit

Core drilling

3

Photo of the façade

2

Photo of the boiler

1

Photo of the electricity meter

2

Photo of the planned location

Back

Confirm

03

Equipment positions

Units and runs placed on the floor plan, backed by photos.

Technical visit

51 rue de Bel air,
Donnery 45450

Dwelling

Façades

Ground floors

Upper floors

Heating and hot water

Ventilation

Photovoltaics

Electricity

Add / remove a section

Client project

E

Current state of the dwelling

Works plan

Heating and domestic hot water

18,2 kW

Leave

Heat pump project

Document the air-to-water heat pump project

Zone to heat

Rooms & emitters

Unit positions

4

Sizing

Estimated heating demand

18,2 kW

Design temperature −7 °C

Check of the radiators’ heat output

8,4 kW

Undersized

Low temperature

19,6 kW

Recommended

Medium temperature

32,1 kW

Oversized

High temperature

Daikin Altherma 3 H HT 18 kW

Output at design temp. 18,0 kW

99 %

Coverage

Back

Confirm

04

Sizing

Calculations confirmed and a summary presented to the customer.

Cengiz Donmez, Whole-home renovation
Cengiz DonmezWhole-home renovationGroupe TILKEO50 employees

“When several teams are involved, everyone needs to work with the same information. Argile helps us standardize our visits and better manage our projects.”

These features should interest you too

The Argile building blocks that pair best with this one, from the survey through to the job site.

Remote design

Remote design

From your desk, qualify the home, sketch the project and give the customer a dependable first estimate before the site visit: you only travel for the projects that are worth it.

Measurements and quantities

Measurements

Your technicians survey the home on a phone, Argile reads the walls end to end, pulls out the wall lengths, the ceiling heights and the floor areas, turns them into quantities per work item and carries them over to the 2D plan, the sizing and the quote, with no double entry.

Customers

/

Camille Martin

Details

Dwelling

Works plans

Quotes

Admin & finance

Quote no. D2026-0042

History

Analysis

Preview

Save

The property

Energy renovation

Information

4

The quote

5

Terms

Next step

The quote

No.

Description

Qty

Unit

Unit price excl.

Total excl.

VAT

Price incl.

1

Installing an air-to-water heat pump

Technical specifications of the heat pump (mandatory)

3 STILL TO FILL IN

Area heated by the heat pump (m²)

e.g. 120

Seasonal energy efficiency ηs (%)

e.g. 126

Controller class

I

II

III

IV

V

VI

VII

VIII

1.1

Installing an air-to-water heat pump

10 600,00 €

11 183,00 €

1.1.1

Air-to-water heat pump 14 kW

1,00

U

3600,00

3 600,00 €

5,5%

3798,00

B

I

U

Heat output +7 °C / +35 °C: 13.00 kW. Heat output -7 °C / +60 °C: 10.10 kW. Seasonal space heating efficiency (35 °C / 55 °C): 150 % / 117 %.

1.1.2

Heat pump fitting and commissioning

1,00

U

7000,00

7 000,00 €

5,5%

7385,00

Add a line

2

External wall insulation (EWI)

2.1

External wall insulation (EWI)

22 500,00 €

23 737,50 €

2.1.1

Polystyrene insulation, R of 3.7 m².K/W or above

120,00

M2

120,00

14 400,00 €

5,5%

15192,00

2.1.2

Insulation labour package

120,00

M2

75,00

9 000,00 €

5,5%

9495,00

Discount

-900,00 €

8 545,50 €

Quotes

Equipment, labour and accessories come from the works plan, VAT applies line by line, grants are deducted from the amount due and the mandatory wording is already written: the quote goes out for signature without a proofread.

FAQ

Browse the answers to the most frequent questions. And if needed, our team is here to help.

Contact us

On a phone or a tablet.

Ready for site visits that fill in the file?

One demo, and you see your expertise proven.

Contact us