Features / Knowing the building

Knowing the building

Knowing the home well before your visit

Request a demo

No commitment, 30-minute demo

Customers

Camille Martin

Details

Dwelling

Works

Quotes

Admin & finance

Characteristics of the home

Source it was seeded from

Certificate · 2278E1234567X

8

/10

Data quality is acceptable

3 certificates/audits found

Change the certificate

Property type

House

Construction period

Before 1945

Living area

105 m²

Ceiling height

250 cm

Heated storeys

2

Overall insulation

Poorly insulated

Heating system

Gas

Domestic hot water

Electric cylinder

Ventilation

Extract ventilation

Listed surroundings

14 Elm Grove, Sheffield S10 2FT

Sharing of energy data

Customer consent obtained

Metered electricity data

Connected to Enedis

Metered gas data

Connected to GRDF

From an address alone, Argile cross-references the public registers and the household's own data to reconstruct the home: plot, volume, year of construction, energy performance certificate, energy consumption, planning and hazard constraints. You arrive with a file already filled in, and the visit confirms rather than discovers.

01

Address, plot and ground footprint

the national address register ties the file to the right building, and the land registry gives the plot, its outline, the party walls and the ground area

177

Plot AB 214 · Ground area 96 m²

14 Elm Grove

Sheffield S10 2FT

Year of construction

Before 1945

Floor area

105 m²

Storeys

2

Heating

Gas

Confirm the address

LiDAR HD · IGN

Height

6,40 m

Storeys

2

Ground area

96 m²

02

Volume, roof and aerial imagery

real height, number of storeys and roof pitch surveyed nationwide, aerial photos and facade views to judge access to the site and where an outdoor unit could go

E

Energy consumption

308 kWh/m²/year

Metered electricity data

Connected to Enedis

Metered gas data

Connected to GRDF

03

Certificates, audits and metered consumption

the certificate on record pre-fills the band, the year, the floor area and the heating system; metered electricity and gas complete it, with the customer's consent

Listed surroundings

Listed surroundings

Yes

Coastal zone

No

04

Planning and heritage rules

local plan, easements and listed-building surroundings: what can block external insulation or an outdoor unit

10

/10

Technical visit

Data quality is very good

Recorded during the technical visit

Kept with the home

05

Confirmed on site, then remembered

3D scan, measurements and openings detected during the visit confirm the registers, and everything stays attached to the home for the next project, with nothing to key in twice

They already trust us

DorémiSaint-GobainIllico TravauxCarrierCrédit Mutuel ArkéaChadapauxLa Maison des TravauxEffyCrédit AgricoleGC GruppeHomeServeDualSunEnsol

+2000

installers

prepare their visits with Argile

10,000

products

kept up to date in our manufacturer catalogues

The journey

Customers

Camille Martin

Details

Dwelling

Works

Quotes

Admin & finance

177

Default

Satellite view

Building matched · Plot AB 214 · Ground area 96 m²

14 Elm Grove, Sheffield S10 2FT

14 Elm Grove, Sheffield S10 2FT

14 Elm Grove, Sheffield S8 9NA

14 Elm Grove Road, Leeds LS6 1AA

01

The address

The address that is keyed in is standardised and tied to the building, down to the plot.

Customers

Camille Martin

Details

Dwelling

Works

Quotes

Admin & finance

Characteristics of the home

Source it was seeded from

Certificate · 2278E1234567X

8

/10

Data quality is acceptable

3 certificates/audits found

Change the certificate

Property type

House

Construction period

Before 1945

Living area

105 m²

Ceiling height

250 cm

Heated storeys

2

Overall insulation

Poorly insulated

Heating system

Gas

Domestic hot water

Electric cylinder

Ventilation

Extract ventilation

Listed surroundings

14 Elm Grove, Sheffield S10 2FT

Sharing of energy data

Customer consent obtained

Metered electricity data

Connected to Enedis

Metered gas data

Connected to GRDF

02

The cross-reference

Argile queries the public registers and reconstructs the home: fabric, performance, constraints.

Customers

Camille Martin

Details

Dwelling

Works

Quotes

Admin & finance

Characteristics of the home

Confirm the details

Source it was seeded from

Technical visit

10

/10

Data quality is very good

3 certificates/audits found

Change the certificate

Property type

House

Construction period

Before 1945

Living area

105 m²

Ceiling height

250 cm

Heated storeys

2

Overall insulation

Poorly insulated

Heating system

Gas

Domestic hot water

Electric cylinder

Ventilation

Extract ventilation

LiDAR HD · IGN

Listed surroundings

14 Elm Grove, Sheffield S10 2FT

Details of the home

Heating

Upper floors

Ventilation

Walls

Windows

Ground floor

03

The visit

The technician confirms on site what the data announced, with the 3D scan and the measurements to back it up.

Customers

Camille Martin

Details

Dwelling

Works

Quotes

Admin & finance

Final rating

Technical visit

E

Set by the worse of the two

Energy consumption

308 kWh/m²/year

CO₂ emissions

62 kgCO₂/m²/year

Energy bill

(estimated)

2 840 €

per year

Heat loss by element

Computed by Argile

11,4 kW

25 %

Roof

30 %

Walls

12 %

Floors

18 %

Windows

15 %

Ventilation

Effect on value

- 38 500 €

- 12 %

against a home rated D

Comfort barometer

Summer comfort

Poor

Winter comfort

Good

Air quality

Very good

04

The file

Sizing, pricing and grants rest on a building that has been described, not estimated.

Cengiz Donmez, Whole-home renovation
Cengiz DonmezWhole-home renovationGroupe TILKEO50 employees

“When several teams are involved, everyone needs to work with the same information. Argile helps us standardize our visits and better manage our projects.”

These features should interest you too

The Argile building blocks that pair best with this one, from the survey through to the job site.

Data access

Data access

Certificates, audits, electricity and gas: Argile fetches the real data of the home and the household, with the customer's consent, so sizing and savings rest on meter readings rather than estimates.

Remote design

Remote design

From your desk, qualify the home, sketch the project and give the customer a dependable first estimate before the site visit: you only travel for the projects that are worth it.

Heat pump sizing note

Calculated to NF EN 12831-1

General information

Beneficiary

Mrs Margaret Hughes

Email

contact@argile.ai

Phone

+44 7700 900457

Works address

7 Rosewood Close, Sheffield

Air-to-water heat pump

Model

Alféa Extensa S. 10

Make

Atlantic

Rated output

10 kW

ηs at 35 °C / 55 °C

195 % / 154 %

COP

3,5

Controller

Classe VI

EPREL no.

2491075

Heat loss of the home

6,0 kW

Output at the design temperature

5,80 kW

3,59 kW

7,78 kW

0 %

60 %

130 %

Coverage of the demand

Equipment output / heat loss of the home

97 %

Sizing of the appliance

Roofs

Transmittance W/m².K

1,8

Area

65,2

Heat loss W/K

135,0

Floors

Transmittance W/m².K

0,6

Area

63,0

Heat loss W/K

15,6

Thermal bridges

Conductivity W/K/m

0,4

Lengths m

33,4

Heat loss W/K

12,5

Façades

Transmittance W/m².K

0,9

Area

162,4

Heat loss W/K

151,4

Openings

Transmittance W/m².K

1,2

Area

5,5

Heat loss W/K

10,9

Air renewal

Air change rate h⁻¹

0,8

Heat loss W/K

102,3

Temperature difference

Outdoor design temperature

-7 °C

Heat pump cut-off temperature

5 °C

Indoor set temperature

19 °C

DeltaT

14,0 °C

Construction coefficient

Volume (area × ceiling height)

378,0 m³

Equivalent G value

1,13 W/m³/K

Sizing report

Compliant with EN 12831-1 and built from the data collected during the site visit, the sizing report comes out of the flow with no extra work, ready for the customer's file.

FAQ

Browse the answers to the most frequent questions. And if needed, our team is here to help.

Contact us

From the public registers — address, land registry, 3D building model and LiDAR, energy performance certificates, planning rules, natural hazards, climate — and, with the customer's consent, from their real electricity and gas consumption.

Ready to know the home before you step inside?

One demo, and you see your expertise proven.

Contact us