Blog/Custom Secondary Glazing: Measuring and Pricing Accurately
Contractors

October 5, 2026

•

6 min read

•

Updated November 14, 2026

Custom Secondary Glazing: Measuring Sizes and Managing Tolerances Without Unpleasant Surprises

Custom secondary glazing is ordered on the smallest of the measurements taken, never on a single one: on old joinery, measure the rebate width and height at three points each and record both diagonals. The fitting clearance is then set with the workshop that makes the frame, based on that survey. On funding, promise nothing the obligated supplier has not confirmed: ECO4 has had secondary glazing measure types since Ofgem's note of 28 September 2026, notifiable only where an RdSAP assessment would recognise the installation.

Contents

Custom secondary glazing is ordered on the smallest of the measurements taken, never on a single one: on old joinery, measure the rebate width and height at three points each and record both diagonals to make the out-of-square visible. The fitting clearance is then set with the workshop that makes the frame, based on that survey, and written on the quote. On funding, promise nothing the obligated supplier has not confirmed: Ofgem's guidance note of 28 September 2026 added secondary glazing to ECO4, but only where an RdSAP assessment would recognise the installation as secondary glazing.

Understanding custom secondary glazing before taking measurements

When secondary glazing makes sense: old joinery and protected areas

Custom secondary glazing is mainly a conservation choice. You are working on old frames of heritage value, on a listed building or in a conservation area where the local planning authority cares about the look of the profiles. Internal secondary glazing does not usually need planning permission unless an Article 4 Direction applies, but a listed building needs listed building consent for any significant works, internal or external. The aim is more comfort without changing the window.

What secondary glazing will not do: limits and funding in 2026

Do not sell it as a window replacement, and quote no Uw until the manufacturer has justified one for the installed assembly. ECO4 is no reason to promise funding either: the two measure types added by Ofgem's guidance note of 28 September 2026 only apply where an RdSAP assessment would recognise the installation as secondary glazing, and the score follows the share of the home's total window area treated, so survey every window rather than only the ones the client points to. Whether a job is funded is for the obligated energy supplier or its managing agent to confirm. The conditions, benefits and limits of secondary glazing in renovation are covered in a dedicated article.

Choosing the right option: fixed, opening, or fitted over an existing sash

Option Measurements to take Key point to watch
Fixed Fitting gap, squareness, available depth Too little clearance on a distorted frame
Opening Opening direction, handle clearance, daylight opening Added weight, hardware to reinforce
Over an existing sash Admissible thickness, clashes with the ironmongery Window that no longer closes after fabrication

Classic trap: taking a single measurement on a twisted frame. Measure at three points per side and write the chosen size on the quote.

Measuring old joinery that is rarely square

Measuring in the right place: rebate, daylight opening, overlaps and sills

First define your reference plane. Record the usable width and height in the frame rebate, then the real daylight opening. Measure the available overlaps, the rebate depth and the condition of the sill. A dated dimensioned sketch, with the opening direction and the hardware, removes ambiguity in fabrication.

Measurement Where to take it Number of readings Unit
Rebate width Top, middle, bottom 3 mm
Rebate height Hinge side, middle, closing side 3 mm
Diagonals Corner to corner 2 mm
Usable rebate depth On each side, at the weakest point 4 mm
Available overlap On each side 4 mm

Taking several readings: diagonals, out of plumb, bowing and twist

On old joinery, a single measurement is worthless. The difference between the two diagonals shows the out-of-square. Check plumb and flatness with a level or laser, note any bowing or twist, and base the order on the most restrictive value.

Spotting the risk areas: sill upstand, glazing beads, irregular gaps

Spot the hard points: a protruding sill upstand, beads that cannot be removed, crushed seals, an irregular rebate. Record the gaps with a rigid rule, especially in the corners. Take photos and mark where a packer or a special profile will be needed to fit without forcing.

Fitting clearance and tolerances: securing custom fabrication

Having the workshop set the clearances from your survey

The clearance is decided before fabrication, and the workshop sets it for its profile system: it must absorb the out-of-plumb, keep a stable bearing, avoid any rubbing when operated and leave the seal its compression range. Your job is to give it a complete survey and have the chosen clearance written down. The secondary glazing is fitted to the system's certified details and the manufacturer's instructions; for the window itself, BS 8213-4 is the code of practice for survey and installation.

Avoiding the single-measurement trap: minimum size and margin

For secondary glazing added to single glazing, record width and height at three points, plus both diagonals. The fabrication size starts from the minimum measurement, less the clearance set by the workshop. A single measurement on a twisted opening gives a frame that cannot be offered up.

Tolerances to write on the quote

What appears on the quote Who sets it
Chosen fabrication size (mm) You, from the minimum measurement
Perimeter fabrication clearance (mm) The workshop, from the survey and its profile
Glazing thickness and make-up (mm) The workshop, according to the available rebate
Admissible hardware load (kg) The hardware manufacturer

Add an approved dimensioned drawing and a survey sheet signed by the customer to record agreement on the sizes.

Profile, opening direction and admissible glazing thickness

Compatibility with the existing frame: sill, upstand, profile grip and overlap

Feasibility is decided at the survey. Check the sill, the condition of the upstand and the available profile grip, then measure the usable overlap all round. If one side lacks overlap, the workshop must know before choosing its profile.

Glazing thickness and type: what the frame really accepts

Open up the rebate. Measure the usable depth, the bead height and the clearance at the back of the rebate. The admissible thickness also depends on the seals and the risk of pinching when tightened. Check the added weight before approving laminated glass.

Opening direction and accessories: handle, stay, stop, ventilation

Confirm the opening direction against the existing hinges, accessibility and stops. Anticipate clashes between handle and reveal. If you add a stay, a stop or a restrictor, plan the fixing into sound timber or a reinforcement. For ventilation, place the air inlets without weakening the profile.

Added weight, reinforcement and scheduling: getting the installation right first time

Calculating the added weight and comparing it with the hardware

Calculate the glass mass (area × thickness × glass density, 2,500 kg/m³), then compare it with the admissible load of the existing hardware. Check possible pull-out from the substrate and fix the screws into the anchor points that genuinely carry load.

Glass thickness (mm) Mass per area (kg/m²)
4 10
6 15
8 20
10 25

Reinforcing hardware and frame without damaging the existing joinery

If the margin is small, reinforce before fitting: an extra hinge, replaced pins, backing plates or longer screws into sound timber. Avoid holes that split old wood, and check the clearance after tightening.

Scheduling: workshop approval, written lead time and a fallback slot

Send a complete survey (opening, direction, rebates, admissible thickness) and get the workshop's approval before production. Ask for its fabrication lead time in writing and only set the installation date on delivery, with a fallback slot in case an adjustment is needed. Plan these checks into your site handover.

For the first estimate, Argile's opening detection lists every window on the facade from photos of the home, with its dimensions and position. The fabrication sizes of the secondary glazing are then taken in the rebate, with a tape.

Key figures

2 measure types

SG_singleupgrade over single glazing and SG_doubleupgrade over double glazing, added to ECO4 by Ofgem's guidance note of 28 September 2026 and notifiable only where an RdSAP assessment would recognise the secondary glazing

100%

Proportion of the property treated under ECO4 when secondary glazing is fitted to every window; otherwise, the share of the home's total window area that receives it

Listed building consent

Needed for any significant works to a listed building, internal or external, whereas internal secondary glazing does not usually need planning permission unless an Article 4 Direction applies

Frequently asked questions

Possibly, but it is not yours to promise. Ofgem's guidance note of 28 September 2026 added two secondary glazing measure types to ECO4, SG_singleupgrade over single glazing and SG_doubleupgrade over double glazing. The measure may only be notified where the installation would be recognised as secondary glazing in an RdSAP assessment, and the proportion of the property treated is the share of the home's total window area that receives it. Whether a job is funded is decided by the obligated energy supplier or its managing agent, so get their written confirmation before mentioning it to the client.

Share this article

Louis Meneteau

Louis is CPO of Argile. An engineer by training, he spent four years validating calculation software in systems engineering, then three years in software product. He turns the installer's daily reality into product workflows: technical survey, sizing, quotes and subsidy files. His articles describe field gestures rather than principles, because he watches them on site before specifying them.

Further reading

With argile

Windows and doors detected automatically

Argile's AI spots the openings on the home's facades: net surfaces calculated for external insulation, joinery listed for the pricing, with nothing to tick off by hand.

ContractorsJuly 22, 2026
Acoustic Windows: Asymmetric Glazing

Asymmetry is not a sales line, it is a way of pulling two critical frequencies apart. A 4 mm pane dips around 3,000 Hz, a 10 mm pane around 1,200: a 4/16/4 unit stacks both dips at the same point in the spectrum, a 10/16/4 separates them by more than an octave. What remains is reading the right index for the noise source, and not giving back on the install what the glazing gained.

5 min read

ContractorsJuly 18, 2026
Security glazing: burglar resistance and thermal performance

"Anti-burglary" is not a product feature, it is a test class. BS EN 356 defines eight, P1A to P5A by ball drop and P6B to P8B by axe attack, and it is BS EN 1627 that says which one goes with the resistance class specified for the whole unit. On the thermal side, laminated glass is paid for in kilograms, not in watts.

5 min read

Reveal your expertise

One demo, and you see your expertise proven.

Contact us