Blog/PCI accounting: converting fuels into kWh
Contractors

November 12, 2026

•

6 min read

PCI accounting (2026): a table for converting your fuel purchases into kWh

To convert your purchases of heating oil, pellets, gas or propane into kWh in your accounting records, remember the simple rule: PCI kWh = quantity purchased × unit PCI, using typical values of 10.0 kWh/L for heating oil, 4.8 kWh/kg for wood pellets, 10.5 kWh/m³ for natural gas and 12.8 kWh/kg for propane, as shown in the conversion table in the article body. For gas, keep in mind that the bill is issued in kWh HHV using a coefficient specific to the delivery point (PCE), which explains the gaps with a “home-made” PCI calculation, and document on the quote or the re-invoicing appendix the PCI/HHV ratio used and your reference conditions (m³ vs Nm³, humidity, density) so it stands up to inspection.

Contents

What “PCI accounting” means in practice

What is kWh conversion used for in accounting and re-invoicing (site, lease, condominium)?

In a PCI accounting framework, you convert each energy purchase (litres, kilograms, cubic metres) into a common unit, PCI kWh. This is used to allocate a cost between units, to recharge an energy base on a site, or to split charges in a lease or condominium setting. It is also the starting point for comparing solutions, then moving on to useful kWh by applying the generator efficiency.

PCI versus HHV: the difference that changes your calculations and comparisons

HHV includes the recoverable heat from condensing water vapour. PCI does not. As a result, for the same fuel, the billed HHV is higher than PCI. For gas, invoices are issued in HHV kWh, using a coefficient specific to the delivery point. A “home-made” calculation from Nm³ to PCI kWh can therefore differ. To compare generators and support a replacement case, choose PCI or HHV from the start and stick to it.

Reference conditions to specify in your tables (unit, moisture, fuel state)

In your tables, note your calculation conditions. Purchase unit and conversion unit (L, kg, m³, Nm³). Fuel moisture and quality (certified pellets, firewood). Density or bulk density used (heating oil, propane). Gas state and measurement basis (standardised vs measured, temperature, pressure). Without this, cross-job comparisons quickly become unusable, especially when the moisture content of firewood causes the actual available energy to vary significantly.

The simple method for turning an invoice into PCI kWh

Step 1: identify the correct quantity on the invoice (litres, kg, m³, kWh, tonnes) without making a mistake

Take the delivered quantity from the invoice line, not the amount. Heating oil and propane in litres, pellets in kg or tonnes, gas in m³ and sometimes already in kWh, electricity in kWh. For gas, billed kWh are calculated from m³ using a coefficient specific to the delivery point (HHV, pressure, altitude). This is the usual reason for discrepancies with a home calculation.

Step 2: apply PCI to obtain PCI kWh (ready-to-copy formulas for Excel)

Principle. PCI kWh = Quantity × unit PCI. In Excel, if B2 = quantity and E2 = unit PCI. =B2$E$2*. If the invoice shows kWh (gas) on an HHV basis, convert: PCI kWh = billed kWh × (PCI/HHV). In Excel. =B2$E$2* with E2 = PCI/HHV.

Step 3: keep a reliable accounting trail (rounding, assumptions and supporting documents)

For PCI accounting, archive the invoice, the calculation file and the assumptions. PCI used, reference conditions, assumed efficiency if you move to useful kWh. Fix rounding rules, for example decimal calculation, then round to the kWh on the posting. Note the delivery date and the allocation period; that is what holds up under review.

PCI conversion table → kWh for heating oil, pellets, natural gas and propane

For clean PCI accounting, set a single assumption for the conditions (gas) and use the PCI of the fuel delivered, not an “internet” value.

Heating oil: litres → PCI kWh (typical values and realistic ranges)

For tracking or re-invoicing, use a PCI per litre, then match it to the generator’s seasonal efficiency to move to useful kWh.

Energy Typical PCI (kWh/L) Realistic range (kWh/L) Assumptions
Heating oil 10.0 9.7 to 10.2 Typical quality, bulk delivery

Wood pellets: kilograms → PCI kWh (watch moisture and quality)

The PCI of pellets mainly varies with moisture content. On site, note the class (e.g. ENplus) and store the batch dry. Do not mix bagged and bulk deliveries in the same ratio.

Energy Typical PCI (kWh/kg) Realistic range (kWh/kg) Assumptions
Pellets 4.8 4.6 to 5.0 Low moisture, standardised quality

Natural gas and propane: m³ or kg → PCI kWh, and why your figures can vary from site to site

Gas is billed in kWh on an HHV basis using a coefficient specific to the delivery point. Your “home-made” PCI calculation can therefore differ. Always record the supplier’s conversion coefficient.

Energy Unit Typical PCI (kWh/unit) Realistic range (kWh/unit)
Natural gas m³ 10.5 9.5 to 11.5
Propane kg 12.8 12.6 to 13.0

Special case for gas: HHV billing and the delivery-point conversion coefficient

Why gas bills are in HHV kWh (not m³): the role of calorific value and pressure

The meter records a volume, but the invoice is in HHV kWh. Gross calorific value varies with the composition of the gas supplied. Measured volume also varies with temperature and pressure at the metering point. The network operator corrects these effects to bring the volume back to reference conditions, then applies the HHV.

Understanding the conversion coefficient: what it represents and where to find it on the bill

The conversion coefficient (kWh/m³) combines the HHV and the pressure-temperature corrections specific to your delivery point (PCE). On the invoice, it appears in the calculation “consumption in m³ × coefficient = kWh”, often near the meter readings, or in the technical breakdown.

Explaining the gap with a “home-made” calculation: a concrete example to resolve disputes

In PCI accounting, you often start from a constant PCI. But the invoice uses a periodic HHV coefficient.

Measured volume (m³) Invoice coefficient (kWh/m³) Billed energy (HHV kWh) Energy on PCI basis (kWh)
120 11.2 1344 1212

To resolve a dispute, reproduce the invoice formula and state the PCI/HHV ratio used in your internal note. Do not mix price per m³ and price per kWh without passing through this coefficient.

Comparing two energies at the right level: from PCI kWh to useful kWh using efficiency

Moving from PCI kWh to useful kWh: include the generator efficiency (boiler, stove, heat pump)

In PCI accounting, first convert the purchase into PCI kWh. For combustion systems (heating oil, gas, wood), delivered energy is calculated in useful kWh: PCI kWh × seasonal efficiency. For a heat pump, you do not start from a PCI. You work in useful kWh via seasonal performance (SCOP): electrical kWh × SCOP. To avoid mistakes, rely on a consistent ETAS, COP and SCOP comparison.

Avoid the trap of price per litre versus price per kWh: a comparison method that does not skew the conclusion

A proper comparison follows three steps. Purchase price per unit. Conversion to PCI kWh. Conversion to useful kWh using efficiency. For gas, the index is in m³ then converted to kWh on an HHV basis using a coefficient specific to the delivery point. If you do a home calculation in PCI, the difference often comes from there, not from the supplier.

Using it to support a replacement decision in 2026: example comparison of heating oil, pellets, gas and propane

Set one common basis of comparison, the cost in €/useful kWh, and you can discuss replacement without endless arguments about the price per litre.

Energy Purchase price (€/unit) Conversion to PCI kWh (kWh/unit) Efficiency or SCOP (1) Cost of useful energy (€/useful kWh)
Heating oil 1.30 10.0 0.85 0.153
Pellets 0.35 4.8 0.90 0.081
Natural gas (billed in HHV kWh) 0.11 0.92 0.95 0.126
Propane 1.80 12.8 0.92 0.153

Frequently asked questions

In practice, set an internal value and document it, for example heating oil around 10 kWh PCI/L, propane around 6.6-6.9 kWh PCI/L, pellets around 4.7-5.0 kWh PCI/kg (certified), firewood highly variable depending on moisture content. The most important thing is consistency across jobs, with a source and conditions (moisture, density, reference basis).

Share this article

Louis Meneteau

Louis is CPO of Argile. An engineer by training, he spent four years validating calculation software in systems engineering, then three years in software product. He turns the installer's daily reality into product workflows: technical survey, sizing, quotes and subsidy files. His articles describe field gestures rather than principles, because he watches them on site before specifying them.

Further reading

ContractorsJuly 4, 2026
Logs, pellets, wood chips: comparing wood fuels

Between logs, pellets and wood chips, the right choice comes down to the practical details. You save time on site when the fuel matches the feed rhythm, the storage space and the level of automation expected. With the right criteria, you secure your client's comfort and your own settings, without oversizing or complicating the installation.

5 min read

ContractorsJune 27, 2026
Renovation and biodiversity: integrating nature into the building

On a job site, every choice matters, not just for energy, but also for the wildlife around the building. You can easily earn points with concrete gestures: preserving the soil, limiting unnecessary lighting, planning simple refuges on facades or roofs. The result: a more pleasant building, and a client who sees the difference right away.

5 min read

ContractorsMay 25, 2026
Heating needs < 15 kWh/m²/year: how to achieve it

Reaching below 15 kWh/m²/year in a retrofit comes down to the details that make the difference on site. You already have the right instincts, the challenge is getting the envelope, airtightness and ventilation right to avoid the “small leaks” that drag down the result. With a clear method and a few checks at the right moments, you secure both performance and client satisfaction.

5 min read

Reveal your expertise

One demo, and you see your expertise proven.

Contact us