The calculation note of décret n° 2025-1048 on the sixth period of the French energy savings certificates (CEE) converts natural gas with 0.9 kWh LHV per kWh HHV, and LPG with 0.92. This gap of about 10 % is the heat of condensation of the water vapour in the flue gases: the HHV counts it, the LHV does not. It concerns you as soon as you put a boiler manual, an ErP product fiche and a gas bill side by side, three documents that do not use the same basis.
HHV and LHV: two ways of counting the same combustion
HHV: the heat of condensation included
Commission Regulation (EU) No 813/2013 defines the higher heating value as the total amount of heat released by the complete combustion of a unit of fuel, with the water in the flue gases brought back to the liquid state. The latent heat released by that condensation is therefore part of the count.
LHV: the water vapour leaves with the flue gases
The lower heating value assumes, on the contrary, that the water formed stays as vapour and leaves through the flue. The LHV is therefore always lower than the HHV. For a fuel without hydrogen the gap would be zero; it grows with the hydrogen content, which puts natural gas at the top of the common fuels.
Units: write the basis next to the kWh
A heating value is expressed in kWh/m³, kWh/kg or MJ/kg, with 1 kWh = 3.6 MJ. A kWh without a basis says nothing: always write “kWh HHV” or “kWh LHV”. For the conversion ratios of each fuel, see our article on the HHV/LHV conversion ratio of fuels.
The ratios used by the French administration
The DGEC, the French directorate general for energy and climate, publishes the factors it uses to go from volumes sold to kWh. These are national calculation values, not the composition of the gas delivered to a given metering point.
| Energy | Published factor | Equivalent HHV/LHV ratio |
|---|---|---|
| Natural gas | 0.9 kWh LHV/kWh HHV | 1.11 |
| LPG | 0.92 kWh LHV/kWh HHV | 1.09 |
| Heating oil | 9,827 kWh LHV/m³ | not published in the note |
Source: presentation note on the calculations of décret n° 2025-1048 of 30 October 2025, table 4.
Natural gas: a national factor, a local composition
The 0.9 factor is enough for a calculation note or a comparison of quotes. The actual energy content varies with the origin of the gas, and it is the conversion coefficient on the bill that reflects it for the customer's home.
Heating oil and wood: start from the published LHV
The note gives no HHV/LHV ratio for heating oil, only its content in kWh LHV. For wood, the LHV depends first on the moisture content of the fuel: a fixed ratio taken from a generic table does not replace the moisture assumption written in the calculation note.
Boiler efficiency: LHV in the manual, HHV on the ErP product fiche
Above 100 % on LHV, below 100 % on HHV
The manual of a condensing boiler often states a useful efficiency above 100 %. The figure is expressed on LHV: the boiler recovers heat that the LHV had not counted in the denominator. It does not create energy. On HHV, the same appliance stays below 100 %.
The European Etas is always on HHV
Commission Regulation (EU) No 813/2013 expresses the useful efficiency and the annual energy consumption of boilers on HHV. The seasonal efficiency Etas on the ErP product fiche is therefore on HHV, and the thresholds apply on that basis, including a minimum of 86 % for a fuel boiler up to 70 kW. The detail of the thresholds is in our article on boiler Etas.
Converting an efficiency from one basis to the other
The conversion fits on one line: η on HHV = η on LHV × (LHV/HHV).
| Useful efficiency on LHV | LHV/HHV factor (natural gas) | Useful efficiency on HHV |
|---|---|---|
| 108 % | 0.9 | 97.2 % |
| 100 % | 0.9 | 90.0 % |
| 92 % | 0.9 | 82.8 % |
This calculation converts an instantaneous efficiency. It does not give the Etas, which also includes controls, electrical auxiliaries and standby losses over a heating season: do not compare a converted manual efficiency with the Etas of another appliance.
Condensation depends on the installation
The condensation gain only exists if the return water is cold enough to bring the flue gases below their dew point. With a return that is too hot or too much excess air, the boiler runs like a conventional appliance, which a combustion analysis brings to light.
Gas bill and calculation note: keep a single basis
What the bill must show
Article 6 of the arrêté of 18 April 2012 requires the supplier to state on the bill the conversion coefficient applied to the billing period and the number of kWh or m³ billed.
| Item | Unit | Where to find it |
|---|---|---|
| Volume consumed | m³ | Meter reading |
| Conversion coefficient | kWh/m³ | Breakdown of the consumption calculation |
| Energy billed | kWh | Total consumption |
Quotes, manuals and audits
- Write the basis in the line heading: “consumption, kWh HHV” rather than a reference at the bottom of the page.
- Keep a single basis for all the works scenarios of the same file, then convert whatever arrives in the other one.
Worked example: reconciling an audit with a bill
The audit states a gas consumption of 12,000 kWh LHV, the bill totals 13,300 kWh. Converted with the 0.9 factor, the audit gives 12,000 / 0.9 = 13,333 kWh HHV: the gap with the bill is now only 33 kWh, not 1,300. Without the conversion, you would have wrongly concluded that the home consumes 11 % more than expected.