Blog/HHV and LHV: understanding the difference and quoting correctly
Contractors

October 9, 2026

•

6 min read

•

Updated November 14, 2026

HHV vs LHV: ratio, boiler efficiency and the gas bill

HHV counts the heat of condensation of the water vapour in the flue gases, LHV does not: for natural gas, the calculation note of the French decree on the sixth CEE period uses 0.9 kWh LHV per kWh HHV. The installer works with three documents that do not use the same basis: the manufacturer's manual, often on LHV, the ErP product fiche, whose efficiency Commission Regulation (EU) No 813/2013 expresses on HHV, and the gas bill. Bringing all three onto a single basis avoids a calculation note that is wrong by around ten percent.

Contents

The calculation note of décret n° 2025-1048 on the sixth period of the French energy savings certificates (CEE) converts natural gas with 0.9 kWh LHV per kWh HHV, and LPG with 0.92. This gap of about 10 % is the heat of condensation of the water vapour in the flue gases: the HHV counts it, the LHV does not. It concerns you as soon as you put a boiler manual, an ErP product fiche and a gas bill side by side, three documents that do not use the same basis.

HHV and LHV: two ways of counting the same combustion

HHV: the heat of condensation included

Commission Regulation (EU) No 813/2013 defines the higher heating value as the total amount of heat released by the complete combustion of a unit of fuel, with the water in the flue gases brought back to the liquid state. The latent heat released by that condensation is therefore part of the count.

LHV: the water vapour leaves with the flue gases

The lower heating value assumes, on the contrary, that the water formed stays as vapour and leaves through the flue. The LHV is therefore always lower than the HHV. For a fuel without hydrogen the gap would be zero; it grows with the hydrogen content, which puts natural gas at the top of the common fuels.

Units: write the basis next to the kWh

A heating value is expressed in kWh/m³, kWh/kg or MJ/kg, with 1 kWh = 3.6 MJ. A kWh without a basis says nothing: always write “kWh HHV” or “kWh LHV”. For the conversion ratios of each fuel, see our article on the HHV/LHV conversion ratio of fuels.

The ratios used by the French administration

The DGEC, the French directorate general for energy and climate, publishes the factors it uses to go from volumes sold to kWh. These are national calculation values, not the composition of the gas delivered to a given metering point.

Energy Published factor Equivalent HHV/LHV ratio
Natural gas 0.9 kWh LHV/kWh HHV 1.11
LPG 0.92 kWh LHV/kWh HHV 1.09
Heating oil 9,827 kWh LHV/m³ not published in the note

Source: presentation note on the calculations of décret n° 2025-1048 of 30 October 2025, table 4.

Natural gas: a national factor, a local composition

The 0.9 factor is enough for a calculation note or a comparison of quotes. The actual energy content varies with the origin of the gas, and it is the conversion coefficient on the bill that reflects it for the customer's home.

Heating oil and wood: start from the published LHV

The note gives no HHV/LHV ratio for heating oil, only its content in kWh LHV. For wood, the LHV depends first on the moisture content of the fuel: a fixed ratio taken from a generic table does not replace the moisture assumption written in the calculation note.

Boiler efficiency: LHV in the manual, HHV on the ErP product fiche

Above 100 % on LHV, below 100 % on HHV

The manual of a condensing boiler often states a useful efficiency above 100 %. The figure is expressed on LHV: the boiler recovers heat that the LHV had not counted in the denominator. It does not create energy. On HHV, the same appliance stays below 100 %.

The European Etas is always on HHV

Commission Regulation (EU) No 813/2013 expresses the useful efficiency and the annual energy consumption of boilers on HHV. The seasonal efficiency Etas on the ErP product fiche is therefore on HHV, and the thresholds apply on that basis, including a minimum of 86 % for a fuel boiler up to 70 kW. The detail of the thresholds is in our article on boiler Etas.

Converting an efficiency from one basis to the other

The conversion fits on one line: η on HHV = η on LHV × (LHV/HHV).

Useful efficiency on LHV LHV/HHV factor (natural gas) Useful efficiency on HHV
108 % 0.9 97.2 %
100 % 0.9 90.0 %
92 % 0.9 82.8 %

This calculation converts an instantaneous efficiency. It does not give the Etas, which also includes controls, electrical auxiliaries and standby losses over a heating season: do not compare a converted manual efficiency with the Etas of another appliance.

Condensation depends on the installation

The condensation gain only exists if the return water is cold enough to bring the flue gases below their dew point. With a return that is too hot or too much excess air, the boiler runs like a conventional appliance, which a combustion analysis brings to light.

Gas bill and calculation note: keep a single basis

What the bill must show

Article 6 of the arrêté of 18 April 2012 requires the supplier to state on the bill the conversion coefficient applied to the billing period and the number of kWh or m³ billed.

Item Unit Where to find it
Volume consumed m³ Meter reading
Conversion coefficient kWh/m³ Breakdown of the consumption calculation
Energy billed kWh Total consumption

Quotes, manuals and audits

  • Write the basis in the line heading: “consumption, kWh HHV” rather than a reference at the bottom of the page.
  • Keep a single basis for all the works scenarios of the same file, then convert whatever arrives in the other one.

Worked example: reconciling an audit with a bill

The audit states a gas consumption of 12,000 kWh LHV, the bill totals 13,300 kWh. Converted with the 0.9 factor, the audit gives 12,000 / 0.9 = 13,333 kWh HHV: the gap with the bill is now only 33 kWh, not 1,300. Without the conversion, you would have wrongly concluded that the home consumes 11 % more than expected.

Key figures

0.9 kWh LHV/kWh HHV

Natural gas (DGEC note, CEE P6 decree)

0.92 kWh LHV/kWh HHV

LPG (DGEC note, CEE P6 decree)

86 %

Minimum Etas on HHV for a boiler up to 70 kW (EU 813/2013)

Frequently asked questions

Look for the written wording “on LHV” or “on HHV”, sometimes noted Hi for the LHV and Hs for the HHV. An efficiency above 100 % is necessarily on LHV. The seasonal efficiency Etas on the ErP product fiche, on the other hand, is always on HHV, since Commission Regulation (EU) No 813/2013 requires it.

Share this article

Pierre-Louis Guhur

Pierre-Louis is CEO and co-founder of Argile. He holds a PhD in machine learning, written at Inria, and renovated a house with his own hands in 2017 before founding the company. On the blog he writes about what he implements in the software: the 3CL-DPE 2021 method, NF EN 12831 and building physics as a calculation engine has to handle them, assumption by assumption.

Further reading

Energy renovationApril 13, 2026
Radon and renovation: understanding and mitigating this natural risk

Radon kills 2,500 to 3,000 people a year in France. Dosimeter measurement, slab airtightness, redesigned ventilation and SSD: the technical levers to master during renovation.

6 min read

Energy renovationApril 9, 2026
GCV/NCV: understanding the fuel conversion ratio

On a quote or an audit, the same gas can display two calorific values, and the gap is not a minor detail. GCV and NCV change the result, so your billed kWh, your stated efficiencies and your comparisons between solutions. By mastering the conversion ratio, you secure your pricing and avoid endless arguments at the end of a job.

5 min read

ContractorsMarch 22, 2026
SCOP and COP: understanding a heat pump's real performance

The gap between an advertised efficiency and real-world comfort often comes down to two simple indicators. Read them correctly and you know right away whether the installation will keep its promises over a full season, not just on a lab test. That's what secures your sizing, your quotes and client satisfaction.

5 min read

Reveal your expertise

One demo, and you see your expertise proven.

Contact us