Blog/Photovoltaic self-consumption: calculating the rate and producing a cost estimate
Contractors

November 6, 2026

•

5 min read

Photovoltaic self-consumption: calculating reliable rates in 2026

To publish a defensible figure, set out two distinct ratios and calculate them from hourly series. The self-consumption rate is calculated as PV self-consumed production / PV production, and the self-production rate (coverage) is calculated as PV self-consumed production / total consumption, with self-consumed(h)=min(Production(h), Consumption(h)) hour by hour as the balance rule, as defined in the body of the article. The worked example in the body sets the order of magnitude without control logic: at 3 kWp, 42% self-consumption and 31% coverage, then at 6 kWp, 27% and 40%, showing that increasing one can reduce the other.

Contents

Set the right indicators before calculating self-consumption

Self-consumption rate: definition, formula and field interpretation

The self-consumption rate measures the share of PV production consumed on site, excluding export. Formula: self-consumed PV energy / PV production. For a defensible self-consumption calculation, work at hourly resolution. Cross-check estimated or measured production (inverter, production meter) with grid import (Linky) to isolate the energy actually consumed at the right time.

Self-production rate (coverage): definition, formula and customer-facing interpretation

The self-production rate relates this self-consumed energy to the site’s total consumption. Formula: self-consumed PV energy / total consumption. This is the indicator that speaks to the client, because it translates into an average coverage of their consumption. Present it as an annual ratio, never as a promise of autonomy.

Why increasing one often reduces the other (with a simple example)

Without a battery or controlled water heater tank, oversizing mainly increases daytime surplus. You improve coverage, but you reduce the self-consumption rate.

Case PV production (kWh/year) Self-consumed (kWh/year) Self-consumption rate (%) Self-production rate (%)
3 kWp 3 300 1 400 42 31
6 kWp 6 600 1 800 27 40

Gather solid input data for a defensible self-consumption calculation

Consumption profile: ideally hourly (otherwise day/night) and how to obtain it

For a serious self-consumption calculation, start from an hourly load curve. The cleanest approach is a Linky export via the Enedis portal or API access (with the client’s mandate). Failing that, rebuild a day/night profile from peak/off-peak tariffs, then align it with the billed monthly kWh.

Production curve: orientation, tilt, shading and location to document

Document the azimuth, tilt, DC power and inverter AC limits. Record shading with time-stamped photos (morning, noon, evening) and note the horizon. For estimation, use a weather-radiation tool such as PVGIS and keep the hourly output, not just the annual figure. To go further on the impact of the installation, see orientation and tilt.

Special cases to include: electric heating, water heater, swimming pool, air conditioning, electric vehicle

Identify controllable loads and their actual schedules. Electric heating and air conditioning follow temperature. The water heater depends on the contactor and reheating cycles. Swimming pools and EVs create peaks. Without sub-metering, make your assumptions explicit and plot the dedicated load curve.

Reliable method: cross-check production and consumption hour by hour

Hourly calculation principle: self-consumed = minimum(production, consumption) for each hour

For a defensible self-consumption calculation, work on an hourly series. At each hour, self-consumed energy is the smaller of the two values. Self-consumed(h)=min(Production(h), Consumption(h)). Surplus(h)=max(0, Production(h)-Consumption(h)).

Why a simple annual ratio overstates self-consumption (the classic trap)

An annual ratio ignores the synchronisation between production and uses. A site that produces mostly in the middle of the day and consumes mostly in the evening may look “good” on an annual basis. Hour by hour, however, you will see a great deal of exported surplus. This shortcut often inflates the result, especially without hot water tank control or a battery.

Practical steps to perform the calculation and present a traceable result

Aim for a traceable result with sourced inputs and archived files.

  1. Retrieve a load curve from the smart meter or a logger. Fill gaps, justify atypical values.
  2. Generate a production curve using a recognised tool (production curve PVGIS, manufacturer software) and document orientation, tilt and shading masks.
  3. Align the timestamps, calculate the hourly minimum, then aggregate by month and year.
  4. Attach a table of assumptions and the method to the quote. You secure your argument against low-cost competitors.

Improve the self-consumption rate without making things up: control and storage

Controlled hot water tank: real impact on the self-consumption calculation depending on schedules

A controlled hot water tank does not “create” self-consumption, it shifts a load. For a defensible self-consumption calculation, cross-check PV production and power draw hour by hour. The heating element (often 1.8 to 3.0 kW) requires a heating window aligned with the solar peak. Also check night reheating (anti-legionella, boost) which worsens the result.

Battery: what it changes on both rates, and the limits (efficiency, power, season)

The battery increases the self-consumption rate by capturing midday surplus, and it can raise the coverage rate too, but only if the charge/discharge capacity and power keep up with the peaks. Factor the round-trip efficiency and depth of discharge into the hourly model. In winter, low production mechanically limits the gain, even with a large capacity. To quantify sizing and profitability, rely on a complete profitability calculation for a domestic storage battery.

Surplus: grid export, surplus sale and on-site uses (2026 watchpoints)

Treat surplus as a balance output, not as a “bonus.” Since 05/06/2026, the self-consumption bonus is no longer part of the case argument for submitted applications. Surplus sale remains governed by a 20-year purchase contract, at a very low level (order of cents). Without storage, prioritise controllable on-site uses, but document the scheduling and power assumptions to avoid an over-optimistic estimate.

Make your figure “solid” in a proposal: assumptions, evidence and margins

Clearly list your assumptions and data sources (readings, scenarios, variations)

For a defensible self-consumption calculation, state plainly what is measured and what is estimated. Attach the evidence, and date it. This protects you in the event of a dispute, and frames the scope.

  • Reference consumption, period covered, hourly resolution, atypical days excluded or kept.
  • Estimated production, orientation, tilt, shading, loss assumptions.
  • Controlled loads, selected control rules, usage constraints, contractual limits.

Show a range of results rather than a single figure (summer/winter, weekday/weekend)

Present a realistic range with three cases: conservative, central, favourable. Distinguish at least summer and winter, weekday and weekend. Remind the client that pushing self-consumption can reduce coverage, and vice versa. Your proposal becomes easy to read, without making unrealistic promises.

Avoid building a profitability argument on an “assumed” profile: how to secure your message

Do not base your margin on a “typical” curve. Anchoring the message in measured data changes everything. Obtain a real history, trace your adjustments, and state what depends on behaviour. If you do not have hourly data, say so, widen the range and explain why.

Key figures

50%

Case A TA

37,5%

Case A TC

33%

Case B TA

Frequently asked questions

Ask the client for a mandate and retrieve the hourly load curve through the Enedis portal (or API), then export it as CSV. Cross-check it with the inverter’s hourly production or a production meter, and calculate self-consumed = min(production, consumption) for each hour. Keep the timestamped exports; they serve as supporting evidence in the event of a challenge.

Share this article

Louis Airy

Louis is COO of Argile. After four years in strategy consulting and close to two as chief of staff in home adaptation and reuse, he joined Argile in March 2024. In daily contact with certified renovation companies, he follows French energy saving certificates, renovation subsidies and reduced VAT, and revises the affected articles whenever a rate changes. What he writes is what he then checks against real quotes.

Further reading

ContractorsJune 6, 2026
Full resale vs self-consumption: which economic model?

Between selling all your production and using it on site, the right choice often comes down to 3 simple points: your client's profile, their usage patterns, and the actual value of a kWh depending on the time of day. As a tradesperson, you save time by asking the right questions upfront, then costing two clear scenarios, with no vague promises.

4 min read

ContractorsJuly 4, 2026
Solar Self-Consumption with a Virtual Battery

Between bills that keep shifting and clients who want more autonomy, you’re often looking for a simple way to make the most of every kWh produced, without adding a technical room or a physical battery. The virtual battery answers exactly that need: it “sets aside” the energy fed into the grid so you can recover it later, with rules and costs that need to be clearly framed from the quote onward. In the lines that follow, we help you clearly explain the principle, the points to watch, and the right field practices to secure your job and keep your clients satisfied.

5 min read

Energy renovationJune 30, 2026
Discount rate and total cost: thinking in life-cycle terms

Between two renovation solutions, the real gap is often decided over 15 or 20 years, not on this month's quote. With the right discount rate, you bring future energy, maintenance and replacement costs back to today's value, and you finally compare on equal terms. That's how you defend a solid technical choice, backed by clear figures.

6 min read

Reveal your expertise

One demo, and you see your expertise proven.

Contact us