Blog/Hygro B mechanical ventilation: the standard for high-performance renovation
Contractors

June 9, 2026

4 min read

Hygro B mechanical ventilation: the standard for high-performance renovation

In renovation, well-adjusted ventilation often makes the difference between a 'clean' project and a client complaining about odours, condensation and mould. With a solution that automatically modulates flow rates according to humidity, you save time on adjustment and secure air quality without over-ventilating. The result: healthier homes and performance that lasts.

Understanding hygro-B mechanical ventilation and its value in renovation

Differences between self-regulating single-flow, hygro-A and hygro-B mechanical ventilation

Self-regulating single-flow mechanical ventilation extracts a near-constant flow rate, summer and winter alike. With hygro-A, the extract points open more or less depending on humidity, but the air inlets remain fixed. With hygro-B, both extract points and air inlets are humidity-controlled. The result: ventilation adapts better to actual use and limits heat loss when the home is dry.

How humidity-controlled regulation works on air inlets and extract points

Each extract point and air inlet includes a sensor (often a textile strip) that expands with humidity. When cooking or showering, the opening increases, and so does extraction. When the air becomes dry again, it closes back up. Regulation is passive, with no electronics, but it requires careful installation.

In which homes hygro-B mechanical ventilation really makes a difference (humidity, occupancy, airtightness)

It's relevant in renovation once insulation and airtightness have improved. It also helps in heavily occupied homes, or ones prone to condensation. In a very leaky house, the effect is limited. You need air inlets in dry rooms and well-sized extraction (see well-sized extraction).

Choosing hygro-B mechanical ventilation suited to your project

Flow rate, network, acoustics: the criteria that avoid callbacks

For hygro-B mechanical ventilation, check the stated regulatory flow rates and, above all, the available pressure. A network that's too long or too bent causes the actual flow rate to drop. Favour rigid or semi-rigid ducting, consistent diameters, and limit crushing. On the comfort side, check the noise level of the unit and extract points, and plan for acoustic sleeves if needed.

Compatibility with insulation and airtightness in high-performance renovation

With a reinforced envelope, ventilation becomes a safety component. Take care with penetrations using airtight sleeves, insulate ducting in cold zones, and keep suitable door undercuts. After installation, adjusting the flow rates and checking the air inlets prevents condensation and recurring odours.

Special cases: kitchen, multiple wet rooms, lofts, very airtight homes

In the kitchen, keep dedicated extraction and an extract point suited to humidity peaks. If there are several bathrooms, size the fan unit and connections to avoid imbalances. In lofts, suspend the unit and keep the filters accessible. In very airtight homes, carry out a measured commissioning — it's your safety net.

Installation and commissioning: the checks that secure performance

Positioning extract points and air inlets: avoiding short-circuiting and discomfort

For mechanical ventilation, fresh air must sweep through the home. Air inlets in living rooms, extract points in wet rooms. The aim is a good sweep of the volumes, without a draught over a bed or a sofa. Also check door undercuts to keep a continuous air path.

Networks: diameters, lengths, bends and airtightness to guarantee flow rates

Respect the planned diameters and limit lengths and bends. Every metre and every angle adds pressure losses, meaning noise or insufficient flow rates. Favour legible routing, well-fixed ducts, and careful connection airtightness (clamps, seals, suitable tapes) to avoid leaks.

Adjustments, measurements and checks: flow rates, pressure, noise and hygro-B operation

At commissioning, measure the flow rates at the extract points and check the pressure available at the fan unit. Adjust the settings to stay within the manufacturer's range. On the comfort side, check the noise level and vibrations. On hygro-B systems, test the opening of the extract points and air inlets according to humidity, then record the values for the project file.

Explaining hygro-B mechanical ventilation to the client and adding value to your quote

Concrete arguments: air quality, comfort, humidity, energy savings in renovation

Hygro-B mechanical ventilation adapts flow rates according to humidity. The air inlets and extract points are automatically controlled. You ventilate more when the bathroom or kitchen needs it, and less the rest of the time. The result: healthier air, less condensation, and a more consistent feeling of comfort. In renovation, it also avoids ventilation running "too strong" continuously, meaning less heat lost outside.

Maintenance and use: simple guidance to preserve the system's efficiency

Good habits keep performance going. Don't block the air inlets. Dust the extract points twice a year. Check that undercut doors still let air pass through. And plan a flow-rate check after installation, then periodically, to keep the right settings (and if needed, revisit the choice between self-regulating vs humidity-controlled mechanical ventilation depending on the home).

Quoting: line items to detail (unit, network, accessories, labour) and relevant options

  • Unit, electrical supply, fixing and any anti-vibration mounts.
  • Duct network, connections, insulation in cold spaces, roof or facade outlet.
  • Hygro extract points and air inlets, sleeves, grilles, acoustic accessories.
  • Commissioning, measurements, adjustments, labour and finishing.

Key figures

10 m³/h

Reduced kitchen flow rate

45 to 135 m³/h

Boost kitchen flow rate

15 to 30 W

Fan unit consumption

Frequently asked questions

You must meet the minimum flow rates of the decree of 24 March 1982 (as amended): in a house, total extraction is at minimum 105 m³/h for a 4-room home and 135 m³/h for a 5-room home (kitchen 45/90/135 m³/h depending on mode, sanitary rooms 15 to 30 m³/h). With hygro-B, flow rates vary, but the design and adjustment must guarantee these minimums under unfavourable conditions (pressure losses, extract points, network). Keep the manufacturer's instructions and the values measured at commissioning to prove compliance.

Louis Meneteau

CPO of Argile

Further reading

ContractorsJuly 24, 2026
Smart thermostat and algorithmic learning

Good heating control is no longer just a fixed setpoint. On the job site, you can offer settings that adapt to the household's rhythms, free heat gains and weather variations, improving comfort without overconsuming. Understanding how the device "learns" and what data it uses helps you avoid vague promises, ask the right questions to the client and secure the commissioning.

5 min read

ContractorsJuly 24, 2026
Renovating a presbytery: religious heritage and performance

Renovating an old building tied to local history is a project where every choice matters. You need to gain comfort and energy efficiency without betraying the character of the place, or getting bogged down in unnecessary details. With a clear method and the right materials, you move fast, cleanly, and secure the result.

5 min read

ContractorsJuly 24, 2026
Cold roof vs warm roof: which configuration to insulate?

On a job site, choosing the insulation under the roof covering isn't just a technical question. You're the one who has to decide between thermal performance, moisture management, available height and ease of installation, without overcomplicating things. With the right approach, you secure comfort in both summer and winter, and you avoid the problems that come back to cost you.

5 min read

Reveal your expertise

One demo, and you see your expertise proven.

Contact us