Blog/Choosing bio-based insulation: selecting the right material by application
Contractors

October 15, 2026

•

6 min read

Bio-based insulation: which material should you choose by application in 2026?

To choose a bio-based insulation product for a given application, start with the thermal resistance required by the CEE sheets; for example, CEE sheet BAR-EN-101 for lofts with lost attic space requires R ≥ 7 m².K/W, and CEE sheet BAR-EN-102 for roof slopes or attic ceilings requires R ≥ 6 m².K/W. With a typical lambda of around 0.036 to 0.045 W/m.K depending on the material, that gives you the approximate thickness to target in your quotation, then you decide based on the actual installation method: cellulose wadding for blown-in attic insulation, wood fibre for sarking or interior lining, hemp for walls, cork for treatment of thermal bridges and other singular details. These thresholds are what an inspection will expect; the rest is decided on site: density, useful summer time lag, and supply price.

Contents

Choosing a bio-based insulation material according to the substrate and expected performance

Lambda, time lag, density: how to read technical data sheets without getting it wrong

When comparing bio-based insulation products, start with three lines. Lambda (W/m.K) determines the thickness needed for a given R value. Density (kg/m³) affects mechanical strength and thermal mass. Time lag only makes sense if the data sheet states the wall build-up assumption (thickness, linings, ventilation).

Price per m², thickness, labour: comparing like with like

In a quotation, align your comparisons on the same thermal resistance (m².K/W) and the same substrate (roof slope, wall, floor). Separate supply, accessories (vapour retarder, adhesives, hangers), and installation time.

Installation rules and site watchpoints (moisture, vapour control layer, settlement)

Treat moisture as a performance requirement. Check airtightness continuity, choose the right vapour retarder for the build-up, and anticipate settlement in lofts by controlling installed density and blown thickness. To size the thickness correctly, use a thermal resistance calculator for building elements so you can hit the target R without over- or under-sizing.

Wood fibre: the right choice for sarking and internal lining

Roof sarking: rigid boards, lambda, time lag and budget in 2026

Item Lambda (W/m.K) Time lag for 200 mm (h) Installed cost 2026 (€/m² excl. VAT)
Rigid sarking board 0,040 to 0,046 8 to 12 140 to 220

For sarking, use rigid boards that are compatible with the underlay membrane. Check the permissible additional load and the load transfer of the fixings. Time lag remains an order of magnitude, and will vary with density and thickness.

Internal wall lining: semi-rigid boards, vapour management and performance

Item Lambda (W/m.K) Interior-side Sd (m) Site target
Semi-rigid board 0,036 to 0,042 Depending on the membrane Consistent installation
Variable vapour retarder 0,25 to 25 Continuity, bonding, junctions

For internal lining, wood fibre is one of the bio-based insulation products that is easy to lay out. Check the substrate moisture content and size the membrane accordingly. Continuous airtightness is better than an extra centimetre of insulation.

When to avoid wood fibre: weight, cost and persistent moisture constraints

Decision point Value (unit) Consequence
Density 110 to 250 (kg/m³) Extra load and handling
Surface weight at 200 mm 22 to 50 (kg/m²) Fixing verification

Avoid it if the substrate remains damp, if the roof is close to its load limit, or if the quote cannot stand up to a lower bid. In those cases, first secure the drying and ventilation protocol, and check the dew point to avoid condensation.

Hemp insulation: a robust solution for walls and lime-hemp build-ups

Internal walls: hemp wool/boards, lambda, time lag and price

For internal lining, hemp wool and hemp boards fit well into a bio-based insulation strategy when you are looking for a vapour-open wall that can tolerate minor moisture incidents. Check density, mechanical strength and vapour retarder compatibility according to the build-up.

Product Lambda (W/m.K) Indicative time lag at 140 mm (h) Supply (€/m² excl. VAT)
Hemp wool roll 0,040 to 0,045 7 to 12 18 to 35
Semi-rigid hemp board 0,039 to 0,044 8 to 13 22 to 45

External walls: where it makes sense, limits and possible combinations (renders, framing)

In ETI, hemp is especially relevant in a timber frame added system with board insulation and compatible render finishes, or in dedicated systems. Watchpoints: fire classification, render adhesion, support and overhang details, and protection from driving rain.

Hemp-lime: use cases, drying time and realistic performance expectations

Hemp-lime is mainly used for thermal and moisture buffering correction, as frame infill, sprayed lining or shuttered construction. Allow for a long drying time before closing up, often several weeks to a few months depending on thickness, humidity and ventilation. In terms of performance, expect moderate thermal resistance: the aim is first regulation and continuity, not record-breaking R values. To go further into installation and the logic of vapour permeability in hemp-lime assemblies, refer to our dedicated guide.

Cork insulation: best suited to singular details and high-risk areas

Thermal bridges, plinth zones, reveals: where cork makes the difference

At singular details, cork is a strong choice when you need an insulation material that is tolerant of accidental moisture and impacts. Typical examples: slab-edge thermal breaks, plinth zones exposed to splashback, and window reveals and supports in external wall insulation. It is also a good option in a bio-based insulation strategy when wood fibre or cellulose would be more exposed.

Expanded cork: lambda, time lag, moisture behaviour and price range

Product Lambda (W/m.K) Time lag at 100 mm (h) Moisture behaviour Approx. supply price at 100 mm (€/m²)
Expanded cork board 0,037 to 0,040 8 to 12 low capillarity, rot-proof, suitable for plinths if properly protected 35 to 70

On façades, remember that thermal resistance mainly comes from thickness. Cork is sold first and foremost for its robustness, not for beating the lowest lambda values.

Balancing cost: reserve cork for the places where it prevents defects

In a quote, justify the extra cost by the risk covered: splashback at the base of walls, condensation in reveals, continuity of insulation around a penetration. Reserve cork for areas where it avoids a render repair, skirting repair or anti-corrosion treatment. The rest of the run can use a more economical insulation material with equivalent performance.

Practical benchmarks for quick decisions by application (comparison tables)

Table by application: sarking, internal lining, wall, singular detail (lambda, time lag, price)

Use Typical bio-based insulation Lambda (W/m.K) Indicative time lag (h) Supply price excl. VAT (€/m²)
Sarking Rigid high-density wood fibre boards 0,038 to 0,048 10 to 14 35 to 70
Internal lining Hemp (boards) or wood fibre (semi-rigid) 0,039 to 0,045 6 to 10 20 to 45
Wall (internal or external insulation) Wood fibre (rigid) or hempcrete (depending on systems) 0,038 to 0,055 7 to 12 25 to 60
Singular detail Expanded cork (boards) 0,037 to 0,040 2 to 5 15 to 35

These ranges give you an order of magnitude for quickly comparing bio-based insulation options. Time lag depends mainly on thickness, density and build-up (underlay membrane, vapour retarder, air gap).

For lofts with lost attic space and roof slopes, cellulose wadding should be treated separately (blown installation, dense-pack installation, installation density, settlement, vapour management). Direct link to cellulose wadding is treated separately.

Questions to ask the client and the auditor in 2026 to secure the choice

  • Primary objective of the works package. Winter, summer, acoustics, or thickness constraint.
  • Target R value per element in the audit. Assumptions for thermal bridges and airtightness.
  • Documentation requirements. Marking, ACERMI, Technical Assessment, and traceability for inspections and grants.
  • Site constraints. Load in sarking, substrate and flatness, membrane continuity, singular details.

Key figures

0,036-0,048 W/m.K

Typical lambda

6-10 h

Time lag at 200 mm

70-140 €/m²

Complete system

Frequently asked questions

In renovation, you should generally aim for R ≥ 6 m².K/W in roof slopes, R ≥ 7 m².K/W in lost-attic spaces, R ≥ 3.7 m².K/W in walls and R ≥ 3 m².K/W in ground floors, in line with the most common eligibility criteria. Ask for the supporting documents (ACERMI, ETA or DTA) and include R, thickness and lambda on the invoice. Also check that the company holds RGE certification for the relevant trade package to secure the client's application.

Share this article

Pierre-Louis Guhur

Pierre-Louis is CEO and co-founder of Argile. He holds a PhD in machine learning, written at Inria, and renovated a house with his own hands in 2017 before founding the company. On the blog he writes about what he implements in the software: the 3CL-DPE 2021 method, NF EN 12831 and building physics as a calculation engine has to handle them, assumption by assumption.

Further reading

With argile

Price your external wall insulation down to the square metre

AI-assisted facade measurements, automatic detection of windows and doors, insulation and render chosen from up-to-date catalogues: Argile takes your external insulation projects from survey to quote without re-entering anything.

ContractorsApril 23, 2026
Render-Based External Wall Insulation: Installation Techniques and Finishes

When you're doing external wall insulation with a rendered finish, everything comes down to the details. Substrate flatness, layout, mechanical fixing, treatment of singular points, each step protects your project from cracks and rework. With a clear method and clean finishes, you gain perceived quality and long-term peace of mind.

5 min read

ContractorsOctober 22, 2026
Roof slopes: assessment before an insulation quote

In a house, roof slopes are the inclined roof planes supported by rafters and purlins, as opposed to an unconditioned attic (non-accessible, insulated at floor level) and a finished attic (insulated under the roof slopes), with framing members you need to be able to name in your quote (rafter, purlin, principal rafter, tie beam). In terms of heat loss, ADEME states that the roof accounts on average for 25 to 30% of a dwelling’s energy losses, which is why you should assess it before adding another layer of insulation. Your basic check hinges on three thresholds: clear height under the slope and acceptable dead volume, continuity of air tightness, and the presence of a roof underlay compliant with best practice (DTU series 40) to prevent moisture and defects in the insulation.

6 min read